Download Print this page

Loading And Operation; Maintenance; Troubleshooting - Power Fist 8058869 Owner's Manual

Air body saw

Advertisement

LOADING AND OPERATION

WARNING: Ensure you read, understand and apply safety instructions before use.
1. Connect the air body to the air hose.
2. Press trigger to operate the tool.
3. Ensure the air supply is clean and does not exceed 90psi while operating the wrench. Too high an
air pressure and unclean air will shorten the product life due to excessive wear, and may be dangerous
causing damage and/or personal injury.
DO NOT use any additional force upon the tool
DO NOT allow tool to free run for an extended period of time as this will shorten its life.

MAINTENANCE

WARNING: Disconnect tool from air supply before changing accessories, servicing or
performing maintenance. Replace or repair damaged parts. Use genuine parts only. Non-
authorized parts may be dangerous.
1. Lubricate the air body saw daily with a few drops of air tool oil dripped into the air inlet.
2. Clean the tool after use. Do NOT use worn, or damaged sockets.
3. Loss of power or erratic action may be due to the following:
a) Excessive drain on the air line. Moisture or restriction in the air pipe. Incorrect size or type of hose
connectors. To remedy check the air supply .
b) Grit or gum deposits in the wrench may also reduce performance. If your model has an air strainer
(located in the area of the air inlet). Remove the strainer and clean it.
4. When not in sue, disconnect from air supply, clean tool and store in a safe, dry, childproof location.
TROUBLE SHOOTING
The following form lists the common operating system with problem and solutions. Please read the from carefully
and follow it.
WARNING: If any of the following symptoms appears during your operating. Stop using
the tool immediately, or serious personal injury could result. Only a qualified persons or an
authorized service center can perform repairs or replacement of tool.
Disconnect tool from air supply before attempting repair or adjustment. When replacing O-rings or Cylinder lubricate
with air tool oil before assembly.견
For any technical questions, please call 1-800-665-8685