Installation Manual
Quidway S5600 Series Ethernet Switches
I. No information on the terminal
Take these steps to address the problem:
1)
Check that:
The power system is operating normally.
The console cable is connected correctly.
2)
Check that the console cable is in good condition and the terminal (HyperTerminal
for example) parameter settings are correct.
II. Illegible characters on the terminal
Make sure you have set on your terminal (HyperTerminal):
Baud rate = 9600
Databit = 8
Parity check = none
Stopbit = 1
Flow control = none
Terminal emulation = VT100
Reconfigure the parameters if their values are different.
Huawei Technologies Proprietary
6-2
Chapter 6 Maintenance and Troubleshooting