4. Operation Description

4.1. Factory Default Settings

Factory default settings are as follows:
• IP address: 192.168.xx.yy (refer to 2.3 Serial Number / MAC Address)
• Mask: 255.255.0.0
• Gateway: 192.168.0.1
• User ID: root
• Password: pass
MAC address = 00-1C-B8-C0-14-B1 → IP address = 192.168.35.69
Factory Default (FD) initialization procedure is as follows:
1. Turn ON the power.
2. Press "Reset" button when Status LED starts blinking rapidly.
3. Release "Reset" button when Status LED blinks slowly. (About 5 seconds after booting)

4.2. Rebooting

Reset can be carried out as follows:
1. Press Reset for 1 second.
When Reset function is activated, Status LED and Network LED will blink together, twice. User
may stop pressing Reset at this point.
2. When "Reset" function has been completed, LEDs will stop blinking.
2010/2-1 O
GANZ MPEG-4 Encoder Series Hardware Manual
Convert the Hexadecimal number to Decimal number
Figure 17. Indicator LEDs and Reset Switch