Ganz ZP-EPC10 Installation Manual

Ganz zp-epc10 protocol converter

Advertisement

Quick Links

Installation Guide

Protocol converter
ZP-EPC10
Always read this manual before installing,
starting up, operating, storing or otherwise handling any part of the system.

Advertisement

Table of Contents
loading

Summary of Contents for Ganz ZP-EPC10

  • Page 1: Installation Guide

    Installation Guide Protocol converter ZP-EPC10 Always read this manual before installing, starting up, operating, storing or otherwise handling any part of the system.
  • Page 2 This installation guide, edition 01 – 05/2000, is valid for use with the the ZP-EPC10 protocol converter (year 2000 version)
  • Page 3: Table Of Contents

    Contents Introduction Intended use EU directives Identification plate Safety Measures Danger by Electric Current Installation Repair and Maintenance Product Description Scope of supply Recommended Accessories Summary of features Connections and Switches Installation Connections Configuration Switching on and off Function test Care and maintenance Cleaning Maintenance...
  • Page 4: Intended Use

    Intended use The ZP-EPC10 protocol converter is designed to provide an interface between the CEC C328 matrix switcher and the dome cameras of the SMD series from CBC. The device converts the data transfer between protocols RS422 and RS485. The unit is designed exclusively for this function.
  • Page 5: Safety Measures

    Repair and Maintenance • Never open the housing of the protocol converter. The device does not contain parts that you can repair or replace yourself. • Ensure that repair or maintenance work is carried out by qualified personnel (electrical engineers). ZP-EPC10...
  • Page 6: Product Description

    Cable made to Belden specifications Summary of features The ZP-EPC10 protocol converter is designed to convert control signals between RS422 (full-duplex) and RS485 (half-duplex) protocol. In addition to adjusting for diffe- rent pin assignments, the unit also converts the protocols used by the CEC C328 video multiplexer and the SMD-type dome cameras manufactured by CBC.
  • Page 7: Connections And Switches

    (hexadecimal in value) CEC C328 matrix switcher 4 OPTIONS switches 9 RCVRS clamp socket Reserved for further extensions For connection of further receivers (e.g. CEC VSD dome cameras) or 5 POWER clamp socket ZP-EPC10 converters To connect the adaptor ZP-EPC10...
  • Page 8: Installation

    You can lock the protocol converter in place on its own or as one of several devices into a RS422 bus on the CEC C328 matrix switcher. The order or position of each of the sin- gle devices has no particular effect because each device has its own address within the bus system. ZP-EPC10...
  • Page 9 5 Answer + (Input) Voltage supply Use an adapter for voltage supply that supplies a DC voltage of between 9 and 24 volts. The maximum power input corresponds to 200 mA. Pin assignment POWER connector 1 Positive 2 Negative (ground) ZP-EPC10...
  • Page 10: Configuration

    In an RS485 cascade, if cabling constraints make it impossible to connect the protocol converter in the first position, then the TERM 2 switch should be in the OFF position (down). The first and last dome camera in such a daisy chain must have their terminal re- sistors connected. ZP-EPC10...
  • Page 11 Annex, page 14). Example 1: Twelve cameras in the system, using addresses 1 to 12 Selector 1 to position 0, selector 2 to position 1 (= address 1) Selector 3 to position 0, selector 4 to position C (= address 12) ZP-EPC10...
  • Page 12: Switching On And Off

    As a minimum, you should make the following checks: Selection of every camera connected to the system Correct operation of functions controlled through the video multiplexer Correct execution of programmed functions (e.g. pre-programmed camera positions) Correct execution of automatic functions (e.g. auto-pan) ZP-EPC10...
  • Page 13: Care And Maintenance

    The device contains agents which can be harmful to the environment. Legal requirements must be respected when disposing of such agents. To dispose of defective equipment or components you no longer need, contact an au- thorised industrial waste disposal or your local waste authority. ZP-EPC10...
  • Page 14: Appendix

    Appendix Appendix Conversion table for hexadecimal addresses dec hex dec hex dec hex dec hex dec hex dec hex dec hex dec hex ZP-EPC10...
  • Page 15: Typical System Configurations

    • Make your selection for the address range, between 1 (lower address) and 12 (upper address). • Assign addresses 1 to 12 to the cameras. • Use the multiplexer to select any camera in the range 1 to 12. ZP-EPC10...
  • Page 16 • Assign addresses 1 to 14 to the cameras connected to the second converter. • Use the multiplexer to select any camera in the range 1 (i.e. camera 1 on the first converter) to 45 (camera 14 on the second converter). ZP-EPC10...
  • Page 17 • Assign addresses 1 to 3 to the SMD cameras. • Use the multiplexer to select any VSD camera in the range 1 to 3. • Use the multiplexer to select any SMD camera in the range 4 to 6. ZP-EPC10...
  • Page 18: Meaning Of Function Keys

    AUX 2 automatic swing between presets 1 and 2 (only vertically) AUX 3 change speed of pan for automatic swing (faster/slower) AUX 4 change speed of tilt for automatic swing (faster/slower) Preset 98 move camera to home position ZP-EPC10...
  • Page 19: Troubleshooting

    1 × 3 pin terminal strip Addressing range 1 ... 256 Operating conditions temperature between +5 ... +40 °C relative humidity up to 90% no condensation Dimensions (W × H × L) 110 × 35 × 165 mm Weight approx. 425 g (including clamps) ZP-EPC10...
  • Page 20 CBC (Deutschland) GmbH CBC (Poland) Sp.z o.o. Hansaallee 191 Ul. G. Morcinka 5, Paw 6 D – 40549 Düsseldorf PL – 01496 Warszawa T: +49 (0) 211 53 06 70 T: +48 (0) 22 638 4440 F: +49 (0) 211 53 06 71 80 F: +48 (0) 22 638 4541 CBC (Europe) Ltd.