Operation Description; Factory Default Settings; Rebooting - Ganz ZN-S1000VE Hardware Manual

1ch h.264 encoder
Hide thumbs Also See for ZN-S1000VE:
Table of Contents

Advertisement

ZN-S100V/ZN-S1000VE HARDWARE MANUAL

4. Operation Description

4.1. Factory Default Settings

Factory default settings are as follows: 
•  IP address: 192.168.xx.yy (Refer to 2.3 Serial Number / MAC Address) 
•  Mask: 255.255.0.0 
•  Gateway: 192.168.0.1 
•  User ID: root 
•  Password: pass 
 
MAC address = 00‐1C‐B8‐C0‐14‐B1 → IP address = 192.168.35.69 
 
To perform the FD (Factory Default) initialization:   
 
ZN‐S1000VE   
Refer to 'Figure 1.' 
1.
Turn off the power. 
2.
Press and hold the Reset button 
3.
Turn on the power. 
4.
Release the Reset button when the Status LED's color is orange and the Data LED's 
color is red. 
5.
Wait for the system to reboot. 
 
 
ZN‐S100V   
Refer to 'Figure 2.' and 'Figure 3.' 
1.
Turn on the power (The Status LED is on). 
2.
Press and hold the Reset button within 1 second. 
3.
Release the Reset button after 3 seconds. 
4.
Wait for the system to reboot. 

4.2. Rebooting

To reboot the system:   
 
ZN‐S1000VE   
Refer to 'Figure 1' 
2010/2-1 D1A.02
Convert the Hexadecimal number to Decimal number
 
15
 