Lift up on the hood latch, and remove the access panel.
3.
After installing hardware options, replace the access panel. Be sure that the panel is securely locked
4.
into place before powering up the server.

Replacing hot-plug fans

The server supports redundant hot-plug fans
server if a primary fan fails.
WARNING:
Remove watches, rings, or other metal objects.
Use tools with insulated handles.
Do not place tools or metal parts on top of batteries.
IMPORTANT:
the same zone, the server shuts down to avoid thermal damage.
Extend the server from the rack, if applicable
1.
Remove the access panel
2.
Remove the malfunctioning hot-plug fan from the server.
3.
("Fan
To prevent personal injury from hazardous energy:
Remove and replace one fan at a time. If the system detects two fan failures in
("Removing the access
locations" on page 21) to provide proper airflow to the
("Extending the server from the
panel" on page 26).
rack" on page 24).