LED
Description
Fan X
One or more of the following conditions exist:
A fan is missing or not properly installed.
A fan failed.
PCI X
One or more of the following conditions exist:
A PCI address parity error was detected on the numbered PCI slot.
A PCI data parity error was detected on the numbered PCI slot.
MEDIA BP
The media backplane is missing or not properly installed.
MEM
A memory board is not properly installed.
MEM BP
A memory backplane is missing or not properly installed.
FSB
One or more of the following conditions exist:
A processor or PPM is missing or not properly installed.
An FSB configuration error was detected.
PROC
A processor is missing or not properly installed.
OVER TEMP
The internal temperature has exceeded operating levels.
NO BOOT
A "no boot" condition was detected.
P84
Switch set to display port 84 codes.