Hot-Swap-Drive Activity And Status Leds - Lenovo ThinkServer RD650 User Manual And Hardware Maintenance Manual

Hide thumbs Also See for ThinkServer RD650:
Table of Contents

Advertisement

Hot-swap-drive activity and status LEDs

Each hot-swap drive has two LEDs on the front.
Figure 37. Hot-swap-drive activity and status LEDs
1
Drive activity LED
Off
On, green
Blinking, green
On, green
On, green
Blinking, green
2
Drive status LED
The drive has failed or is not present.
Off
Off
The drive is present but not in use.
The drive is active and data is being transferred.
Off
Blinking rapidly (about
The RAID controller is identifying the drive.
four flashes per
second), amber
On, amber
One of the following situations:
• The drive has failed. Replace the drive.
• The status of the drive is Unconfigured Bad. Replace the drive.
• The status of the drive is Offline. You can change the drive status
For detailed information about using the ThinkServer MegaRAID
SAS Software, refer to the ThinkServer MegaRAID SAS Software
User Guide. You can obtain the most up-to-date documentation for
your server from the Lenovo Web site at:
http://www.lenovo.com/UserManuals
The drive is being rebuilt.
Blinking slowly (about
one flash per second),
amber
2
1
Description
Note: If a drive in a RAID array is removed and then reinstalled
while the server is on, the status of the drive will be identified as
Unconfigured Bad. In this case, do not replace the drive. You
can change the drive status into Unconfigured Good using the
ThinkServer MegaRAID SAS Software.
into Online using the ThinkServer MegaRAID SAS Software.
.