Stator Voltage Test - Lincoln Electric COMMANDER SVM153-A Service Manual

Lincoln electric welding system user manual
Table of Contents

Advertisement

F-34
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician
or machine operator and will invalidate your factory warranty. For your safety and to avoid
electrical shock, please observe all safety notes and precautions detailed throughout this
manual.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-
bleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
TEST DESCRIPTION
This test will determine if the correct AC voltages are being generated from the stator
windings.
MATERIALS NEEDED
Volt/Ohmmeter
3/8" wrench
3/4" Wrench
This procedure should take approximately 40 minutes to perform.
TROUBLESHOOTING & REPAIR

STATOR VOLTAGE TEST

WARNING
COMMANDER 500
F-34

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Commander 500

Table of Contents