F-37
AUXILIARY
LEADS #5B, #5E,
#8, #9, #11, #12
(BEHIND PANEL)
AUXILIARY POWER AND WELD
WINDINGS TEST
1. Start the engine and run at high idle (1900
RPM).
power.
2. Check for 115-132VAC at leads #9 to #5B.
Also check for 115-132VAC from leads #8 to
#5E.
See Figure F.15 and the Wiring
Diagram.
TROUBLESHOOTING & REPAIR
STATOR VOLTAGE TEST (CONTINUED)
FIGURE F.15 – AUXILIARY LEAD TEST LOCATION
Do not load welding or auxiliary
COMMANDER 500
3. Check for 230 to 264VAC at leads #11 to
#12.
See Figure F.15 and the Wiring
Diagram.