Lincoln Electric COMMANDER SVM153-A Service Manual page 125

Lincoln electric welding system user manual
Table of Contents

Advertisement

F-72
OUTPUT RECTIFIER BRIDGE DIODE REMOVAL AND
REMOVAL AND REPLACEMENT (CONTINUED)
8. Inspect the mounting surfaces of each new
diode. Remove all burrs and wipe clean.
Do not use steel wool or any abrasive
cleanser on the diode mounting surface.
9. Apply a thin (0.003" to 0.007") uniform
layer of Penetrox A13 joint compound
(T12837-1) to the heat sink mounting sur-
face.
a. Do not apply compound to the diode
stud or mounting threads.
b. Apply two drops of Loctite 271 to the
diode stud threads before tightening.
DIODE STUD SIZE
TROUBLESHOOTING & REPAIR
3/4 - 16
3/8 - 24
COMMANDER 500
NOTE: The diode threads must be clean and
free of defects so that it can be finger tightened
before applying torque. A "slip" type torque
wrench must be used to tighten the diode.
10. Tighten the diode to the specifications in
the following table.
11. Connect the stator leads and diode pigtail
leads as labeled at disassembly.
12. Replace the output panel.
FOOT POUNDS
25-27
10 ± 0.5
F-72
INCH POUNDS
300-324
125 +0/-5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Commander 500

Table of Contents