F-36
OUTPUT LEADS
(BEHIND PANEL)
OUTPUT PANEL
6. Using the 3/8" wrench, remove the three
screws holding the lower front panel (output
panel) to the case front assembly. Then
remove the front two screws holding the top
of the panel. These are accessed in the
TROUBLESHOOTING & REPAIR
STATOR VOLTAGE TEST (CONTINUED)
FIGURE F.14 – OUTPUT PANEL REMOVAL
COMMANDER 500
GREEN
GROUND
LEAD
SCREWS
control box, on the bottom at each side of
the box. See Figure F.14. Carefully move
the lower front panel to the right side. Note
the green ground lead will still be attached.
F-36