M6100, M5300, and M7100 Series Managed Switches
Enter the IP address of the switch in the web browser address field.
4.
The default IP address of the switch is 169.254.100.100.
The Login screen displays.
Enter the user name and password.
5.
The default admin user name is admin and the default admin password is blank, that is,
do not enter a password.
Click the Login button.
6.
The web management interface menu displays.
Select System > Management > System CPU Status > CPU Threshold.
7.
Configure the Rising Threshold value.
8.
Notification is generated when the total CPU utilization exceeds this threshold value over
the configured time period. The range is 1 to 100.
Configure the Rising Interval value.
9.
This utilization monitoring time period can be configured from 5 to 86400 seconds in
multiples of 5 seconds.
Configure the Falling Threshold.
10.
Notification is triggered when the total CPU utilization falls below this level for a
configured period of time.
The falling utilization threshold must be equal to or less than the rising threshold value.
The falling utilization threshold notification is made only if a rising threshold notification
was done previously. Configuring the falling utilization threshold and time period is
optional. If the Falling CPU utilization parameters are not configured, then it takes the
same value as Rising CPU utilization parameters. The range is 1 to 100.
Configure the Falling Interval.
11.
The utilization monitoring time period can be configured from 5 seconds to 86400
seconds in multiples of 5 seconds.
Configure the CPU Free Memory Threshold value in KB.