9.2.3) BOARD 15.14.250 "POWER INVERTER SECTION" (fig. 19)
Full-bridge power inverter
WARNING: before taking measurements described, open solder-jumper K2 with the machine unplugged!
Note: solder-jumper K2 causes a break in the inverter's power supply circuit and is normally closed (it may be opened to test
the power source; also see chapter 10 below)
Description of boards
Unless otherwise specified, all measurements sholud be taken with the boards in their slots and connected accordingly
Power source / Mode
Component
OFF
MF11
OFF
MF12
OFF
MF15
OFF
MF16
Power source / Mode
LED
ON / TIG 2T*
L13
ON / TIG 2T
L14
ON / TIG 2T
L15
ON / TIG 2T
L16
* Note: TIG 2T = 2 STROKE TIG (see owner's manual)
V S
G
V S
+0.25 Vdc
+0.36 Vdc
+0.25 Vdc
+0.36 Vdc
+0.25 Vdc
+0.36 Vdc
+0.25 Vdc
+0.36 Vdc
Status
ON (with torch trigger pulled)
ON (with torch trigger pulled)
ON (with torch trigger pulled)
ON (with torch trigger pulled)
D
23