Internal diagnostic messages are supplied by the LEDs on board 15.14.250.
The LEDs indicate operating status of the relevant part, as described in the table below:
Led
Meaning
L1
-15 Vdc supplied by 15.14.250 for 15.14.250
control section
L2
+15 Vdc supplied by 15.14.250 for 15.14.250
control section
L3
+5 Vdc supplied by 15.14.250 for 15.14.250
control section
L4
+24 Vdc supplied by 15.14.250 to power front panel
L5
+48 Vdc supplied by 15.14.250 to power front panel
L6
-15 Vdc supplied by 15.14.250 for 15.14.250
UPFR section
L7
+15 Vdc supplied by 15.14.250 for 15.14.250
UPFR section
L8
Supply under voltage alarm
L9
Supply overvoltage alarm
L10
UPFR active
L11
Output power enabling (also see sect. 7.1 "output power"
LED and sect. 9.2.4 "pot signal")
L12
Thermal cutout alarm
L13
Gate MOS 11 present
(output power enabling)
L14
Gate MOS 12 present
(output power enabling)
L15
Gate MOS 15 present
(output power enabling)
L16
Gate MOS 16 present
(output power enabling)
Description of diagnostic indications
Status (in regular operating conditions)
ON
ON
ON
ON
ON
ON
ON
OFF = everything OK
ON= unit lockup
OFF = everything OK
ON = unit lockup
ON (brightness depends on output current delivered)
MMA: ON
TIG: ON if torch trigger pulled
OFF = everything OK
ON = unit lockup
MMA: ON
TIG: ON if torch trigger pulled
MMA: ON
TIG: ON if torch trigger pulled
MMA: ON
TIG: ON if torch trigger pulled
MMA: ON
TIG: ON if torch trigger pulled
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wu 15Genesis 200 tlh

Table of Contents