Inter-Function Delay; Special Keyboard Feature - CipherLab 1564 User Manual

Barcode scanner
Hide thumbs Also See for 1564:
Table of Contents

Advertisement

1564 Barcode Scanner

2.4.4 INTER-FUNCTION DELAY

By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254
in units of millisecond, to match the computer response time of the keyboard interface.
Such delay time is inserted between every function code (0x01 ~ 0x1F) being
transmitted. The longer the delay time is, the slower the transmission speed will be.
1) Read the barcode above to specify the inter-function delay.
2) Read the
"Decimal
(millisecond).
3) Read the "Validate" barcode on the same page to complete this setting.

2.4.5 SPECIAL KEYBOARD FEATURE

By default, this interface employs special function codes (0x01 ~ 0x1F) defined in the
Keyboard Wedge Table. However, users may want to get rid of these special codes within
the barcodes to avoid data error. You can decide whether to apply the special keyboard
feature. For further details please refer to
80
User Guide
Value" barcode on page 263 for the desired inter-function delay
Inter-Function
Delay... (*0~254)
Keyboard Wedge
Table.
*Apply
Bypass
Enter Setup

Hide quick links: