1564 Barcode Scanner

4.13.3 GS1 DATABAR EXPANDED (RSS EXPANDED)

When GS1 formatting for GS1 DataBar Expanded is enabled, code ID transmitting will be
disabled.
The settings below apply to Group II symbologies only:
GS1 DataBar Expanded
GS1 DataBar Expanded Stacked
Transmit Code ID
Decide whether to include the Code ID in the data being transmitted.
GS1 Formatting for GS1 DataBar Expanded
Decide whether to enable GS1 formatting for GS1 DataBar Expanded. When enabled, the field
separator and application ID mark characters will be automatically added to the output data.
142
User Guide
Enable GS1
Formatting
*Disable GS1
Formatting
Enable RSS-14 &
RSS Expanded
(Groups I, II)
*Disable
*Transmit
RSS Expanded Code ID
Do Not Transmit
Enable GS1
Formatting
Enter Setup

Hide quick links: