Escea ST900 User Manual
Hide thumbs Also See for ST900:

Advertisement

GAS FIREPLACE USER GUIDE
ST900
NORTH AMERICA
Ce manual est disponsible en Français sur demande
www.escea.com
630297_0_Manual_User_ST900_US
SERIAL NUMBER 43000 AND ABOVE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ST900 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Escea ST900

  • Page 1 GAS FIREPLACE USER GUIDE ST900 NORTH AMERICA Ce manual est disponsible en Français sur demande www.escea.com 630297_0_Manual_User_ST900_US SERIAL NUMBER 43000 AND ABOVE...
  • Page 2 ADJUSTABLE SAFETY GATE TO KEEP TODDLERS, YOUNG CHILDREN AND OTHER AT RISK INDIVIDUAL OUT OF THE ROOM AND AWAY FROM HOT SURFACES Manufactured By: Escea Ltd, 17 Carnforth Street, Green Island, Dunedin 9018, NZ. Ph: +64 3 4788220 For distribution details see: www.esceasales.com...
  • Page 3 Quick-Start Guide NOTE: Make sure to install batteries in the remote handset and the receiver (refer to page 5 of this manual) before operating this fireplace for the first time. Using the remote handset: To start your fireplace: 1. Press and hold the button until you hear 2 beeps and the handset shows a blinking series of lines.
  • Page 4: Table Of Contents

    Normal operating Sounds and Smells > Warrantee The ST900 electronic control system is designed to work within the temperature range of 32°F to 176°F, with a humidity level that is non condensing. This is to ensure safe operation of the electronic and gas control system.
  • Page 5: Advanced Operation

    flame height in Manual mode, or control the room temperature in Thermostat mode. The remote has a maximum range of 30 feet, and because the remote works by radio frequency, it does not need to be aimed at the ST900 for it to operate. Signal Indicator...
  • Page 6: Designated Low Fire And High Fire

    Advanced Operation To Turn on the Fireplace Flame Height Adjustment Remote One-Button Startup (Default) To increase the flame height Press the button until a press and hold the button series of blinking lines and until the desired flame height is two short beeps confirms attained.
  • Page 7: Modes Of Operation

    Advanced Operation Program Mode Operation Modes To turn on: Thermostatic Mode Press the button. , 1 or 2, ON or The desired room temperature OFF will be displayed. is set by the user and the fireplace adjusts its flame height automatically to achieve this desired room temperature.
  • Page 8: Touch Pad Wall Switch

    Advanced Operation Selected Setting the ON time (Program 1) , 1, ON is displayed, displayed briefly and hours flash. 8. Change the hour by pressing the button. 9. To confirm, press the button. , 1, ON is displayed, displayed briefly and minutes flash. 10.
  • Page 9: To Turn Off Gas To Appliance

    Advanced Operation Touch Pad Transformer plug location This should only be used when the remote handset is unavailable. To access this touch pad you must The transformer plugs into the receiver as shown in the remove the fascia (refer to page 8 of this manual). It is diagram below.
  • Page 10: Clearances

    TV location decisions rest solely with the householder and the manufacturer / distributor will not be held liable for any adverse affects on a TV located near to the ST900 fireplace that may be caused by heat. The drawings below are suggestions that may be used as a GUIDE for those consumers who do decide to locate their TV above an ST900 gas fire.
  • Page 11 COMBUSTIBLE materials, then the below shows the maximum allowable size clearances to mantles or protruding for mantles or protruding surfaces surfaces mounted above an ST900 may mounted above an ST900 be as shown by the shaded area in the diagram below...
  • Page 12: Cleaning And Maintenance

    Removing the ST900 Fascia Ensure the fascia is allowed to cool before handling. The ST900 fascia attaches to the fire by four hooks. To remove the fascia, simply lift it upwards 15-20mm, and pull towards you. Care should always be taken when handling the fascia.
  • Page 13 Do not operate the appliance if the glass has been broken, damaged, or the glass is not properly positioned/hooked onto the appliance. Cleaning your ST900 The unit must be cold before starting any form of maintenance or cleaning. The glass can be cleaned using standard window cleaner. If you wish the clean the inside of the glass, you can remove the glass assembly by following the instructions on page 8.
  • Page 14 Ensure your strokes still follow the direction of the grain or brush finish. 6. Ensure that no film is applied to the glass of your Escea Gas Fireplace. If applied accidentally, wipe off with an absorbent microfibre cloth.
  • Page 15: Normal Operating Sounds And Smells

    Sounds and Smells Note: Each time the fire is lit from cold the glass will fog up with condensation. This is normal and the condensation will disappear within a few minutes once the glass heats up. Sounds It is possible that you will hear some sounds from your gas appliance. This is perfectly normal due to the fact that there various types of materials used within your appliance.
  • Page 16: Warrantee

    Where an Escea product is covered by a parts and labor warrantee, the warrantee covers both the repair by Escea of the defective part or the provision of a spare part to replace the defective part and the installation of that part.
  • Page 17 3.1.11 Subjective factors (e.g. like noise or smell) that have been investigated by Escea (or their technicians) and confirmed to be within normal operational parameters; 3.1.12 Any differences in fireplace appearance from Escea promotional images that is due to printing limitations, environmental factors or gas type.
  • Page 18 Where you make a claim under this warrantee, an authorized repairer may need to attend your premises to inspect the Escea product. We may charge you a service call fee if a repairer will be required to travel more than 30 miles from the nearest service centre to your location.