Page 1
• INSTRUCTIONS MUST BE LEFT WITH THE CONSUMER AND THE CONSUMER TO RETAIN THEM FOR FUTURE REFERENCE. Manufactured by: Escea Ltd, PO Box 5277 Dunedin NZ, Ph: +64 3 478 8220, email: info@escea.co.nz For contact details of your local Escea distributor or dealer please visit www.escea.co.nz...
Page 2
This Gas Fire is for outdoor use only. Batteries Not Included The EF5000 electronic control system is designed to work within the temperature range of 0°C to 70°C, with a humidity level that is non condensing. This is to ensure safe operation of the electronic and gas control system.
Product Description: The escea EF5000 flame effect gas fire is designed for outdoor use only. This appliance requires no flue and must be permanently installed into a cavity. It may be installed into a timber cavity. The fire is controlled by the user from a touch panel that is situated on the lower right hand side of the stainless steel fascia, or if the ‘wall mount’...
Amp capacity. Connect the transformer to the fire by putting the Positive wire into the Red terminal of the control tray, then connect the Negative wire to the Black terminal. THIS MUST ONLY BE DONE BY AN AUTHOURIZED ELECTRICIAN 630159_2 EF5000 Installation Guide R-emotion - NZ...
Creating the Cavity: The dimensioned drawing below shows the size of opening that must be created to install the unit. The EF5000 can be installed into timber cavities with timber walls. Cavity Dimensions: Minimum Cavity Dimensions 1010 mm 585 mm...
Typically an outdoor space is not enclosed but, any enclosure in which the appliance is used shall comply with one of the following: An enclosure with walls on all sides, but at least one permanent opening at ground level and no overhead cover. 630159_2 EF5000 Installation Guide R-emotion - NZ...
Page 8
Rectangular areas have been used in the above diagrams, the same principles apply to any other shaped area. In the case of balconies, at least 20% of the total wall area shall be and remain open and unrestricted. 630159_2 EF5000 Installation Guide R-emotion - NZ...
Insert the supplied rubber plug and cut it as shown below to allow the gas pipe to pass through, keeping the plug as air-tight as possible. Note: a flexible stainless steel hose is available from your escea retailer. Part #801240 630159_2 EF5000 Installation Guide R-emotion - NZ...
Using the supplied Stainless Steel screws, fasten the fire to the cavity through these drilled holes. Ensure that the fire is securely located and free from movement. 630159_2 EF5000 Installation Guide R-emotion - NZ...
10.1 The regulator that is supplied in the fire MUST NOT BE REMOVED. Removal of the regulator, or replacing it with one not intended for use with an Escea EF5000, will void the limited appliance warranty. 10.2 The EF5000 must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½...
14.1 With the glass in position, fix the stone cartridge to the fire by using the two supplied screws in the location shown below. Do this before the fascia is fitted. 630159_2 EF5000 Installation Guide R-emotion - NZ...
Before fitting the fascia, the hooks must be attached using the screws supplied. Ensure the two wires connecting the fascia to the fire are securely connected, as per section 11.0. The EF5000 Stainless Steel fascia is attached to the combustion box by four ‘hooks’ on the corners of the fascia.
16.0 Placement of Fuel Bed: EF5000 fuel beds should be evenly spread out with a maximum one layer of media. Do not heap or mound the fuel bed media and attempt to get an even spread across the top of the burners.
17.0 Operating Instructions: The EF5000 is operated by the touch control panel located on the Right hand side outer edge of the fascia. The basic operations possible from the touch control are ON/OFF and manual adjustment of the flame height.
Page 17
Once the pilot flame has been running for at least 6 seconds press the FLAME UP (1) button to start the gas to the two main burners 17.6 The EF5000 has 4 flame positions: PILOT flame only, LOW burner flame, MEDIUM burner flame and HIGH burner flame. 17.7 Adjusting the flame height...
Cleaning of the burners and ceramic stones can be carried out using a brush and a dry cloth and should be done at least annually. This will remove carbon or soot build-up. 19.0 Electrical Schematic 630159_2 EF5000 Installation Guide R-emotion - NZ...
Page 20
Front Burner Aeration Hole 11mm Rear Burner Aeration Hole 11mm 56000 54000 For any inquiries, please contact info@escea.co.nz or contact our Client Services Centre at 03 478 8220 Escea Gas Fires 17 Carnforth Street PO Box 5277 Green Island Dunedin 9058...