Monitoring Point Setting; Muting Monitoring When Online; Importing Menu Settings; Exporting Menu Settings - Tascam CD-9010CF Owner's Manual

Cd/solid state player
Table of Contents

Advertisement

Monitoring point setting

You can set whether the monitoring output signal is from before
or after the Online fader.
1.
Press the MENU button to open the
2.
Open the
menu.
SYSTEM
3.
Select
.
MONITORING  POINT
4.
Press the DATA dial to move the cursor right to select the
setting.
Turn the DATA dial to set the monitoring point.
5.
(default value): Monitor the signal before the
PreFader
Online fader
: Monitor the signal after the Online fader
PstFader
6.
After completing the setting, press the HOME button to
return to the Home Screen.
NOTE
The monitoring point setting is retained even when the power is
turned OFF.

Muting monitoring when online

You can set whether or not monitoring output is automatically
muted during online playback.
1.
Press the MENU button to open the
2.
Open the SYSTEM menu.
3.
Select
.
MON  MUTE  ONLINE
4.
Press the DATA dial to move the cursor right to select the
setting.
5.
Turn the DATA dial to set whether monitoring output
muting during online playback is ON or OFF.
• Options:
,
(default value)
OFF
ON
After completing the setting, press the HOME button to
6.
return to the Home Screen.
NOTE
The monitor mute online setting is retained even when the power
is turned OFF.
8 – Other settings and information display
screen.
MENU
screen.
MENU

Importing menu settings

You can import settings that have been saved on a CF card and
use them as the unit's menu settings.
Load a CF card containing saved menu settings.
1.
Press the MENU button to open the
2.
Open the
menu.
SYSTEM
Select
3.
.
MENU  IMPORT
Press the DATA dial to open a confirmation pop-up
3.
message.
4.
Press the DATA dial again to import settings from the CF
card.
5.
When importing completes, the pop-up disappears and
the
menu screen reopens.
SYSTEM
6.
Press the HOME button to return to the Home Screen.
NOTE
The LCD CONTRAST, LCD BRIGHTNESS and LED BRIGHTNESS
settings of the SYSTEM menu are not imported.

Exporting menu settings

You can save the unit's
screen settings to a CF card.
MENU
1.
Press the MENU button to open the
2.
Open the
menu.
SYSTEM
3.
Select
.
MENU  EXPORT
3.
Press the DATA dial to open a confirmation pop-up
message.
4.
Press the DATA dial again to export the settings to the CF
card.
5.
When exporting complete, the pop-up disappears and
the
menu screen reopens.
SYSTEM
6.
Press the HOME button to return to the Home Screen.
NOTE
The LCD CONTRAST, LCD BRIGHTNESS and LED BRIGHTNESS
settings of the SYSTEM menu are not exported.
screen.
MENU
screen.
MENU
45
TASCAM CD-9010CF

Advertisement

Table of Contents
loading

Table of Contents