10.2
Inverter failure
PV Over Voltage
1)
Check the open PV voltage to see whether it is greater than or too close to 450Vdc for APV 1700-2M-
TL-US or 500Vdc for APV 2300-2M-TL-US and APV 3100-2M-TL-US.
2)
If PV voltage is less than 450Vdc for APV 1700-2M-TL-US or 500Vdc for APV 2300-2M-TL-US and APV
3100-2M-TL-US, and the problem still occurs, please contact your local Service Centre.
Consistent Fault
1)
Disconnect PV (+) or PV (-) from the input, restart the PV inverter.
2)
If this fails to clear the fault, please contact our Service Centre.
> If there is no display on the panel, please check PV input connections.
If the voltage is higher than 150V, please contact your local Service Centre.
> During periods of little or no sunlight, the PV-Inverter may continuously start up and shut down. This is
due to insufficient power generated to operate the control circuits.
Error message
Error 100
Error 101
Error 102
Error 116
Error 117
Error 118
Error 119
Error 120
Error 121
Error 122
RADIUS Home
Meanings
Suggestion
2.5V reference voltage
Mainly caused by control board.
fault
Contact RADIUS Solar Service.
Communication fault.
Secondary processor can't receive data from primary processor.
Secondary processor
Restart the inverter to see if the error arising immediately or several minutes later,.
can't receive data from
Contact RADIUS Solar Service.
primary processor
Consistent fault.
The 2 processors' (in control board) calculation results are different.
The 2 processors'
Disconnect PV (+) or PV (-) from the input to restart the PV-Inverter.
(in control board)
Check if the problem arising immediately when start or connected to grid, or several
calculation results are
minutes later after connected to grid.
different.
Contact RADIUS Solar Service.
EEPROM fault
EEPROM has some problem
Contact RADIUS Solar Service.
Relay fault
Problem of control board or relay in main board
Initialization model
Inverter model error or haven't been set.
fault
Contact RADIUS Solar Service.
GFCI module damage
Return the inverter for repair
Output current sensor
Current sensing device fault. May concern with main board or control board.
fault.
Internal communica-
Primary processor can't receive data from Secondary processor.
tion fault.
Restart the inverter to see if the error arising immediately or several minutes later.
Primary processor
Contact RADIUS Solar Service.
can't receive data from
secondary processor.
Bus voltage too high
Control board or main board problem. Contact RADIUS Solar Service.
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Radius apv 2300-2m-tl-usRadius apv 3100-2m-tl-us

Table of Contents