Fiber-Optic Light Guide; Led Illumination; Supply (Line) Lamp 25W; Coaxial Illuminator - Leica MS5 User Manual

M stereo microscopes
Hide thumbs Also See for MS5:
Table of Contents

Advertisement

46
Fiber-optic
light guide
Cold light source Leica CLS series
The Leica CLS se ries is a high-performance
line
for h
gh
light
intensity with in the smallest possible space
and
flicke r-free
wh ite
light with the lowest possible thermal effect on the ob-
jects. The comprehe nsive line of
accessories
enables unlimited
use. The CLS series
is
produce
d
of antistatic material.
Whe
n
using the
ring
la mp
(0
76 mm)
on
the
planachromatic
objective
0.8x
~
0
80
mm),
a spec
ial
adapte
r
(10 447 078) is
required.
For a deta
il ed
information, refer to the user manual Lei ca CLS.
o
The clamp of the fib er-optic light guide cannot be
attached to the microscope carrie
r
AX.
r;--,
.
fS;;:
~Turn
the clamp
in
g screw out ofthe clamp.
~r
~
Hold the clamp in the opening of the
microscope carrie
r.
~
Push the clamping sc rew through the
holes in the microscope carrier an
d
in
the broader part ofthe
cla
mp, and screw
it finger-tight to the narrow part of the
clamp.
'·{
0~
·
~
'
\ ~ \\
u~
~
\~
Il
l
~
~Inse rt
the fiber-optic light guide into the clamp.
~Switch
on the power unit.
~A
l
ign
the light spot with the
object.
~
Retighten the clamping screw.
Leica LED illumination
The Lei ca LED1000 (Lase
r
Em itting Diode) illu mination is ava il-
able with ring illuminator and/or spot and su itable for ro utine
tasks with
the
Leica MS5, MZ6,
MZ7~,
MZ9s stereomicroscopes.
LEDs, which do not
develop
any heat, are used as
illuminators.
The
calor
tempe rature measures 5000 K (daylight).
For details see the separate instructions for use for the LED
ill
umination.
Leica
M Stereomicroscopes
-
llluminatio ns
rn
Supply (line) lamp 25W
Foll
ow the safety instructions given on
page 7.
~
Fit the lamp holder and lamp as
desc ribed below (incide nt-l ight
lamp 6
V/1
0 W).
~
Co nnect the 25 W su pply Oine)
lamp to the powe
r
su pply.
~
Switch on the su pply (line)
lamp.
~Align
the lig ht
spot
with the object
as desc
ribed.
Coaxial illuminator
o
This ill uminator is for obse rving and photog raphing flat,
highly-reflecting objects such as wafers, integrated circ uits
and pol ishe
d
metal sections.
The coaxia
l
incident
lig
ht housing fits like an accessory tube
between the optics carrier and the binocular tube, or between
the optics ca rrier and the phototube (page 50).
• For the MZ7s and MZ9s, fit the objective
m
preferably to the spacer ring (10 446 300),
,
,
.
page 32. Th is wil
l
comp letely ill uminate
-
the largest field of view.
~
~
• A quarter-wave plate is req uired when the microscope
carrie
r
AXis used in the vertical position.
~Using
the clamping screw, secure the quarter-wave plate to
the objective mount.
~Using
the knu rled ring, turn
the
quarte r-wave plate unti
l
the
required effect is obta
in
ed.
Please observe the notes on the use of
the
aperture in the
AX microsco pe carrier (p. 19).
Le
ica
M
Stereomic
roscopes
-
Illuminations
47