Samsung OfficeServ 7030 Installation Manual page 13

Hide thumbs Also See for OfficeServ 7030:
Table of Contents

Advertisement

SAFETY CONCERNS
Warning
VIII
WARNING
Caution for grounding
- Do not connect the OfficeServ 7030 system's grounding wire to the building's
power conduit.
- The power and grounding installation should comply with the local standard;
all related works should be conducted according to the local standard.
- External grounding is required to prevent bodily injuries or system damages
from lightning, static electricity or voltage surge.
- Unplug the AC power cord before connecting the grounding wire. Failure to do
so may cause bodily injury.
- The OfficeServ 7030 system should be connected to a protective-ground
outlet.
- The GND in the back panel of the OfficeServ 7030 system should be grounded.
Using double-pole/neutral fusing
Do not attempt to repair the system after only removing the fuse from the neutral
line, doing so may cause electric shock. If the repair is required, unplug the
system's power cord before proceeding.
AC power connection restriction
Connect the system's AC power to a separated AC outlet. If the AC power is used
together with other equipments, a system failure or fire may occur due to static
electricity and/or voltage drop.
Caution for using expansion cabinet
Do not put the expansion cabinet on top of basic cabinet horizontally. Doing so
may cause a system failure or fire due to rising internal heat of the basic cabinet.
© SAMSUNG Electronics Co., Ltd.

Advertisement

Table of Contents
loading

Table of Contents