24
INSTALLATION
1. Bottom of hull
2. Anti ventilation plate
ENOW00007-0
CAUTION
Before beginning the running test, check
that the boat with maximum capacity
loading floats on the water in a proper
attitude. Check the position of water
surface on the driveshaft housing. If the
water surface is near the bottom cowl-
ing, in high waves, water may enter the
engine cylinders.
Incorrect
outboard
height or existence of underwater
object(s), such as hull bottom design,
bottom surface conditions or underwa-
ter accessories, can cause water spray
possibly reaching the engine through an
opening of the bottom cowling during
cruising. Exposing the engine to such
conditions for extended periods can
lead to severe engine damage.
1
10−30 mm
(0.4−1.2 in)
2
ENOF00015-A
motor
mounting
ENOM00830-0
Mounting bolts
1
2
1. Bolt (12 × 105)
2. Washer (small diameter)
3. Nut
4. Washer (large diameter)
351 (13.82)
327 (12.87)
163.5
Ø12.5
125.5
251 (9.88)
View A
ENOW00008-0
CAUTION
Mounting bolts should be installed with the
bolt head at inside surface of the transom.
Mounting bolts installed with the threaded
end at the inside surface of the transom
can cause personal injury.
4
3
ENOF00017-A
163.5
Ø12.5
125.5
ENOF00018-A