Transporting And Storing The Generating Set - SDMO VARIO 1000i Instruction And Maintenance Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 15
5.3.6 Cleaning the generating set
Never wash the generating set with a water jet or high pressure cleaner.
IMPORTANT
Remove all dust and debris from around the exhaust silencer (A–14).
Wash the outside of the generating set using a sponge and water with a mild detergent added (e.g. car shampoo).
A cleaning foam may be used and wiped off using a soft, absorbent cloth.
Rinse using the sponge with fresh water to remove any trace of cleaning product.

6. Transporting and storing the generating set

6.1. Transport and handling conditions
Before transporting the generating set, check that the bolts are correctly tightened, close the fuel tap (if fitted) and disconnect the
battery (if fitted). The generating set should be transported in its normal operating position; never lay it on its side. A pump unit should
be handled gently and brusque movements should be avoided. Ensure that the place where it is to be stored or used is carefully
prepared beforehand.
6.2. Storage conditions
This procedure for storing the generating set or protecting it over the winter must be respected if the generating set is not used for a
period of between 2 months and 1 year. For longer periods of storage, it is recommended to contact your nearest agent or to start up
the generating set for a few hours every year, and respect the storage procedure after doing so.
This operation requires the addition of a preservative to the fuel tank or complete drainage of the fuel tank (use a suitable container).
Open the inspection flap.
With a suitable container in place and without closing the fuel tap, open the fuel tank cap and remove the fuel filter.
Allow the fuel to completely drain into the container (drainage of the tank and pipes) then fit a new fuel filter.
Close the fuel tank cap, place the vent tab in the "ON" position and use the starter (position
Allow the generating set to operate until it runs out of fuel.
Close the fuel tap and the vent tab ("OFF"), wipe off any trace of fuel and check for leaks.
Top up the oil while the engine is warm.
Open the access cover for the spark plug, remove it (E–2) and pour approximately 3 ml (1 tablespoon) of clean engine oil into the
cylinder via the spark plug orifice; then refit the spark plug and close the access cover.
Pull the starter-recoil reel handle (A–7) 3 or 4 times to distribute the oil in the cylinders and protect them from corrosion.
Clean or replace the air filter (depending on the condition) and close the inspection flap.
Clean the generating set and cover it with a protective cover to protect it from dust.
Store the generating set in a clean, dry place. Do not store it on its side.
) to start the generating set.
18

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vario 2000iVario 3000i

Table of Contents