1. This appliance is for use with only the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases.
2. This heater needs fresh air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety
shutoff system. The ODS shuts down the heater if not enough fresh air is available. See Air for Combustion and
Ventilation, pages 6 through 8. If heater keeps shutting off, see Troubleshooting, pages 16 through 18.
3.
Keep all air openings in front and bottom of heater clear and free of debris. This will ensure enough air for proper
combustion.
4.
If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced.
5.
Do not run heater:
•
Where flammable liquids or vapors are used or stored.
•
Under dusty conditions.
6.
Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from
these products may create a white powder residue within burner box or on adjacent walls or furniture.
7.
Always run heater with control knob at PILOT/IGN, LOW or HIGH locked positions. Never set control knob
between locked positions. Poor combustion and higher levels of carbon monoxide may result.
8.
Do not use heater if any part has been under water. Immediately call a qualified service technician to inspect
the room heater and to replace any part of the control system and any gas control which has been under water.
9. Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.
10. Operating heater above elevations of 4,500 feet could cause pilot outage.
QUALIFIED SERVICE AGENCY
Only a qualified agency should repair and service heater. The term "qualified agency" means any individual,
firm, corporation, or company that either in person or through a representative is engaged in and is responsible for:
Repairing, or servicing equipment; that is experienced in such work; that is familiar with all precautions required;
and that has complied with all the requirement of the authority having jurisdiction.
PRODUCT FEATURES
SAFETY PILOT
This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot shuts off the
heater if there is not enough fresh air.
PIEZO LGNITION SYSTEM
This heater is equipped with an electronic piezo control system. This system requires AAA batteries (provided).
LOCAL CODES
Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The
National Fuel Gas Code, ANSI Z./ NFPA 5.
*Available from:
American National Standards Institute, lnc.
1430 Broadway
New York, NY 10018
In the State of Massachusetts, unvented gas-fired space heaters shall be prohibited in bedrooms and bathrooms.
National Fire Protection Association, lnc.
1 Batterymarch Park
Quincy, MA 02269-9101