FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property
damage, personal injury or loss of life.
A.
When lighting the pilot, follow these instructions exactly.
B.
BEFORE LIGHTING, smell all around the appliance area for gas. Be sure to smell next to the floor be-
cause some gas is heavier than air and will settle on the floor.
C.
Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or
turn by hand, don't try to repair it, call a qualified service technician or gas supplier. Forced or attempted
repair may result in a fire or explosion.
D.
Do not use this appliance if any part has been under water. Immediately call a qualified service technician
to inspect the appliance and to replace any part of the control system and any gas control which has been
under water.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch, do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
LIGHTING INSTRUCTIONS
1.
STOP! Read the safety information on the front and back of warning plates.
2.
Check that gas supply to heater is connected to heater.
3.
Push in gas control knob slightly and turn clockwise
4.
Wait five (5) minutes to clear out any air gas. Then smell for gas, including near the floor. If you smell gas,
STOP! Follow "B" in the safety information on the warning plate. If you do not smell gas, go to the next
step.
5.
Push in gas control knob slightly and turn counterclockwise
knob for five (5) seconds (see Figure 11).
Note: The first time that the heater is operate after connecting the gas supply,the control knob should be
depressed for about thirty(30) seconds.This will allow air to bleed from the system.
6.
With control knob pressed in, push down and release ignitor button. This will light pilot. If needed, keep
pressing ignitor button until pilot lights.
7.
Keep control knob depressed for ten (10) seconds after lighting pilot. If pilot goes out repeat steps 5,6 and 7.
8.
Turn control knob counterclockwise
to the OFF position.(see Figure 11)
to ON position. The burner should light.


to"PILOT/IGN" position. Press in control