10 DETERMININg ThE FLUE LENgTh AND FLUE pACKs REqUIRED
IMpORTANT.
The boiler MUST be installed in a vertical position
FLUE KITs
pack B - telescopic supplied as standard
pack B - optional non-telescopic
pack D - optional extension kit for side flue or rear flue outlet.
Concentric Flue screw Retaing Kit - optional kit for mechanical
fixing of flue joints.
Finishing Kit - Supplied as an optional extra.
Refer to 'Flue Extension Ducts'
Note. MaxiMuM Flue lengThs:
24
30
35
24, 30 35
24, 30 & 35
90
Elbow KIt 60/100 (EquIValEnt FluE lEngth rEsIstancE = 1m)
o
45
Elbow KIt 60/100 (EquIValEnt FluE lEngth rEsIstancE = 0.6m)
o
mInImum horIzontal FluE lEngths - tElEscoPIc tErmInal = 350mm
(Centre line of turret to outside of wall terminal)
REAR FLUE
155 + S = 200mm
Wall Thickness X
197mm 197mm
16
INsTALLATION
- 9M (horizonTal Flue)
- 8M (horizonTal Flue)
- 6M (horizonTal Flue)
- 7.5M (rooF Flue)
- 5M PriMarY anD 17M seConDarY is a TYPiCal Max.
Flue lengTh. (For alternative details refer to Powered Vertical
Instructions)
- onE PIEcE tErmInal = 285mm
155 mm
Dimension x - Wall thickness.
Dimension L - Wall thickness plus boiler spacing.
Dimension s - Optional stand-off frame depth 45mm.
155 + S = 200mm
sIDE FLUE
Wall Thickness X
197mm 197mm
Side flue length L
+
Ideal Logic
Combi -
155 mm
continued . . . . .
Installation and Servicing