IDEAL LOGIC + Combi 24 Installation And Servicing page 10

Hide thumbs Also See for LOGIC + Combi 24:
Table of Contents

Advertisement

1
BOILER DIMENsIONs, sERVICEs & CLEARANCEs
The boiler connections are made on the boiler connection tails.
Refer to Frames 29-32.
The following minimum clearances must be maintained for
operation and servicing.
Additional space will be required for installation, depending upon
site conditions.
side and Rear Flue
a. Provided that the flue hole is cut accurately, e.g. with a core
drill, the flue can be installed from inside the building where
wall thicknesses do not exceed 600mm (24"). Where the
2.5
43
65
Gas Inlet
Front clearance
The minimum front clearance when built in to a cupboard is 5mm
from the cupboard door but 450mm overall clearance is still
required, with the cupboard door open, to allow for servicing.
*
Bottom clearance
Bottom clearance after installation can be reduced to 5mm.
This must be obtained with an easily removable panel, to enable
the consumer to view the system pressure gauge, and to provide
the 100mm clearance required for servicing.
REAR FLUE ONLy
MIN. Top clearance required = 165 mm
10
2.5
from case
Side flue
dim. A
57
38
39
65
gENERAL
space into which the boiler is going to be installed is less
than the length of flue required the flue must be fitted from
the outside.
Installation from inside ONLy
b. If a core boring tool is to be used inside the building the
space in which the boiler is to be installed must be at least
wide enough to accommodate the tool.
395
700
Horizontal length of flue from
CL of boiler to outside wall
24
0.5 m
1.0 m
1.5 m
2.0 m
2.5 m
3.0 m
3.5 m
4.0 m
4.5 m
5.0 m
5.5 m
6.0 m
6.5 m
7.0 m
7.5 m
8.0 m
8.5m
9.0 m
Ideal Logic
all dimensions in mm
sIDE FLUE ONLy
Top clearance required
(MIN.) Dim. A
30
35
0.5 m
0.5 m
1.0 m
1.0 m
1.5 m
1.5 m
2.0 m
2.0 m
2.5 m
2.5 m
3.0 m
3.0 m
3.5 m
3.5 m
4.0 m
4.0 m
4.5 m
4.5 m
5.0 m
5.0 m
5.5 m
5.5 m
6.0 m
6.0 m
6.5 m
N/A
7.0 m
N/A
7.5 m
N/A
8.0 m
N/A
N/A
N/A
N/A
N/A
+
Combi -
Installation and Servicing
165 mm
170 mm
185 mm
200 mm
210 mm
225 mm
250 mm
260 mm
265 mm
275 mm
290 mm
300 mm
320 mm
330 mm
345 mm
360 mm
370 mm
385 mm

Hide quick links: