5 Inch Network High-definition Speed Dome User Manual
PATROLS NUMBER
The dome provides 8 patrols numbering from 1 to 8.
PATROL NUMBER
<PATROL EDIT>
<PATROL PERVIEW>
<PATROL CLEAR>
PATROL EDIT
The EDIT PATROL settings menu is shown in Figure 3.3.17. A patrol can be configured with 32 presets.
To edit a patrol:
1.
Use the Up and Down direction buttons to select the preset to be edited.
2.
Use the Left and Right direction buttons to select among PRESET, DWELL TIME and SPEED.
3.
After having selected the item to be edited, use the Up and Down direction buttons to set values.
4.
Follow the same steps to edit the other presets. Click the Down button to enter the next page.
The preset edited in the patrol can be modified or deleted as well. In default setting, the preset number is initialized as 0, the dwell
time is 2 seconds (0-30 seconds selectable) and the patrol speed is level 30 (level 1-40 selectable).
5.
Press IRIS+ to save the current settings or press IRIS- to cancel settings and return to the previous menu.
Note: The patrol speed of the dome is shown as below:
Level
1
4
7
10
13
16
19
22
25
28
31
34
37
40
PATROL PREVIEW
Enter the PATROL PREVIEW menu to view the current patrol if defined, which enables the dome to scan among the presets as
predefined.
PATROL CLEAR
Enter the PATROL CLEAR menu to clear the current patrol.

3.3.7 PATTERNS

A pattern is a memorized, repeating series of pan, tilt, zoom, and preset functions that can be recalled with a command from a
<PATROLS>
1
BACK
EXIT
Figure 3.3.16
Speed(
)
°/s
Level
0.3
2
6
5
12
8
18
11
30
14
45
17
60
20
80
23
110
26
140
29
170
32
230
35
290
38
350
Figure 3.3.17
Speed(
)
°/s
Level
2
3
8
6
14
9
20
12
35
15
50
18
65
21
90
24
120
27
150
30
190
33
250
36
310
39
20
Speed(
)
°/s
4
10
16
25
40
55
70
100
130
160
210
270
330

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents