  • Page 1 AUTOMATION 119DU8 5 EN FOR SWING GATES INSTALLATION MANUAL AX302304 AX402306 / AX412306 AX71230 English...
  • Page 2: Important Safety Instructions

    WARNING! important safety instructions: READ CAREFULLY! • REMISE PREVENT ANY RISK IT IS FORBIDDEN FOR USERS TO PERFORM ANY OPERATIONS THAT ARE NOT • E MPLOY THIS PRODUCT ONLY FOR THE USE FOR WHICH IT WAS EXPRESSLY MADE EXPRESSLY REQUIRED OF THEM AND WHICH ARE NOT LISTED IN THE MANUALS OR ANY REPAIRS .A.
  • Page 3: Legend Of Symbols

    But whereas with reversible operators it is merely advisable, with irreversible ones, beyond 4 m, it is obligatory. 3 Reference Standards The company CAME S.p.A. is ISO 9001 quality certified; it has also obtained the ISO 14001 environmental safeguarding certification. CAME engineers and manufactures all of its products in Italy.
  • Page 4: Technical Features

    4.2 Technical features GEARMOTOR AX302304 GEARMOTOR AX402306 / AX412306 GEARMOTOR AX71230 Control board power supply: 230V AC Control board power supply: 230V AC Control board power supply: 230V AC 50/60Hz 50/60Hz 50/60Hz Motor power supply: 230V AC 50/60Hz Motor power supply: 230V AC 50/60Hz Motor power supply: 230V AC 50/60Hz Max draw.: 1,5A...
  • Page 5: Installation

    5 Installation Installation must be carried out by expert qualified personnel and in full compliance with current regulations. 5.1 Preliminary checks Before installing, do the following: • Make sure you have suitable tubing and conduits for the electrical cables to pass through and be protected against mechanical damage;...
  • Page 6: Standard Installation

    5.4 Standard installation 1) AXO operator 2) Control panel 3) Reception antenna 4) Flashing light 5) Selector switch 6) Photocells 7) Electric cable junction box 8) Mechanical gate stops 9) Photocell column 5.5 Installing the operator The following illustrations are only examples, given that the space available for anchoring the operator and accessories may vary from gate to gate.
  • Page 7 A, the opening angle and gate speed are increases, while the gearmotor thrust is decreased. Pillar bracket Gate bracket AX302304 - AX402306 - AX412306 AX71230 Gate leaves of up to 4m Gate leaves of up to 7 m...
  • Page 8 Insert the bushing (lubricated) into the pillar bracket’s hole. The bracket has holes that allow the opening angle to be changed. Secure the tail joint to the bracket. Screw M8 x 35 Bushing Tail joint AX302304 Nut UNI 7474 M8 AX402306 - AX412306 Bushing Tail joint...
  • Page 9 Open the gate leaf and insert the pin into the gate bracket and secure it using a washer and nut. Gate bracket UNI6593 Ø8 washer Screw UNI5739 M8x10 Release the gearmotor (see paragraph on manual release), completely open the gate leaf, loosen the nuts of the opening mechanical stop and position it up against the attachment pin, then secure it.
  • Page 10: Connecting To The Control Panel

    5.6 Manual release of the gearmotor Slide open the small door that protects the release, insert the tri-lobed key and turn it. 5.7 Connecting to the control panel For the electrical connection procedures, use the junction box and branching boxes. Connecting the 230V a.c.
  • Page 11 5.8 Outward opening installation (non-issued) Supplementary bracket TABLE 1 TABLE 2 Opening Opening 90° 1100 90° Weld pillar bracket to the non-issued supplementary bracket, while gate is open, then secure the brackets to the pillar, making sure the “A” and “B” quotas shown in table 1 are met. Weld, or secure with proper screws, the gate bracket, making sure the “E” quota is met, as shown in table 1.
  • Page 12 Fully close the gate-leaf, place the mechanical stop against it with the pin attachment and fi x it in place. Attachment pin Opening mechanical stop Fully open the gate-leaf, place the mechanical stop against it with the pin attachment and fi x it in place. Attachment pin Closing mechanical stop Connect the gearmotors to the panel as shown in the diagram.
  • Page 13: Maintenance

    7 Maintenance Extraordinary maintenance Before doing any maintenance, cut off the power supply, to prevent any hazardous situations caused by accidentally activating the operator. ☞ Periodic maintenance log kept by users (every six months) Date Notes Signature Extraordinary maintenance The following table is for logging any extraordinary maintenance jobs, repairs and improvements performed by specialized contractors. ...
  • Page 14: Troubleshooting

    CAME S.p.A. employs a UNI EN ISO 14001 certified and compliant environmental protection system at its plants, to ensure that environmental safeguarding. We ask you to keep protecting the environment, as CAME deems it to be one of the fundamental points of its market operations strategies, by simply following these brief guidelines when disposing.