Be sure the diskette is not damaged. Run the diskette utility on the diskette (CHKDSK on some
2.
systems).
Be sure the diskette is properly inserted. Remove the diskette and reinsert correctly into the drive.
3.
Be sure the diskette drive is cabled properly. Refer to the server documentation.
4.
A problem has occurred with a diskette transaction
Action: Be sure the directory structure on the diskette is not bad. Run the diskette utility to check for
fragmentation (CHKDSK on some systems).
Diskette drive cannot read a diskette
Action:
If the diskette is not formatted, format the diskette.
1.
Check the type of drive you are using and be sure you are using the correct diskette type.
2.
Drive is not found
Action: Be sure no loose connections (on page 41) exist with the drive.
Non-system disk message is displayed
Action:
Remove the non-system diskette from the drive.
1.
Check for and disconnect any non-bootable USB devices.
2.
Diskette drive cannot write to a diskette
Action:
If the diskette is not formatted, format the diskette.
1.
Be sure the diskette is not write protected. If it is, use another diskette or remove the write protection.
2.
Be sure you are attempting to write to the proper drive by checking the drive letter in the path
3.
statement.
Be sure enough space is available on the diskette.
4.
DLT drive problems
Server cannot write to tape
Action:
If the drive cleaning light is on, clean the drive.
NOTE: DLT cleaning cartridges are good for only 20 uses. If the cleaning cartridge is near that limit and the
drive cleaning light is still on after running the cleaning cartridge, use a new cleaning tape to clean the
drive.
If the tape is write protected, remove the write protection. If the tape still does not work, insert
another tape into the drive to see if the original tape is faulty.
Refer to the tape drive documentation to be sure the type of tape being used is supported by the
drive.
Check each tape cartridge that has been used in the drive to verify its condition and inspect its tape
leader to verify it is not damaged and is in the correct position. After you locate any bad cartridges,
dispose of them. A working tape drive may drop its leader when using bad cartridges, indicating
Troubleshooting 59