C
B
A
A
INSTALLATION & SERVICING INSTRUCTIONS
8 716 115 219c (03.2010)
D
H
I
F
G
C
E
D
A
F
B

FLUE INSTALLATION

1
Remove retaining screw (A) to swing
control panel assembly (B) outwards to
its full extent.
2
Remove screws (C) from inside of casing.
Lift front of top panel (D) to release.
Pull forwards to disengage rear retainer
(E), then lift panel (D) away from boiler.
3
Pull clip (F) outwards to release the
E
expansion vessel(G).
4
Swing expansion vessel (G) outwards.
Note: for easier access to the inner case, the
expansion vessel can be unhooked (by removing
the retaining screw on the hinge) lowered and
moved to the side. Take care not to overstretch
the flexible pipe connections.
5
Release four screws (H) to remove the
inner case cover ( I ).
A
B
CONVERT FROM REAR FLUE OUTLET:
The boiler is supplied ready to fit a rear flue
outlet. To flue from the sides or top of the boiler,
follow the procedure below:
1
Remove and discard the required side or
top 'knock-out' panel (A) from the outer
casing (B).
2
Remove the flue outlet blanking plate
comprising: cover (D) and gasket (E) from
the inner casing (C) by removing the three
screws (F).
3
Refit the outlet blanking plate over
the rear flue outlet.
25