▶ When the condensate connections are complete, pour
approximately 200 to 250ml of clean water through the inner flue
opening on top of the boiler to fill the siphon.
149mm
Fig. 32 Pipe work dimensions
5.5

Flue turret/adaptor installation

The flue turret/adaptor for the appliance is secured using three retaining
screws (figure 33, item [1]) which come in position on the appliance.
To ease assembly of flue components, apply silicone
lubricant to sealing surfaces.
Refer to the manual supplied with the flue kit for
complete installation instructions.
For plume management effective lengths and the
effective flue lengths, refer to details in section 4.7.
Refer to figures 33 & 34.
▶ Remove the three inner flue tube retaining screws [1].
The inner tube will be held in place in the appliance.
▶ Check the appliance flue seal [2] is correctly seated and apply
silicone grease.
Greenstar Ri Compact
ErP
6720813282 (2015/07)
23mm
WALL
23mm
l l
W a
Fig. 33 Flue turret centre
[D]
170mm
[W] 195mm
▶ Align the flue turret/vertical adaptor to the appliance flue outlet with
flat facing [3] to the rear of the appliance.
The flue turret/adaptor should be pushed straight down, on to the
appliance.
▶ The three inner flue tube retaining screws [1] are, re-used for the flue
turret and replacement retaining screws [4] supplied with the
adaptor kit are used to secure turret/adaptor to the appliance.
3
1
Fig. 34 Flue turret/adaptor connection
Additional notes and reminders:
• Ensure that all cut lengths are square and free from burrs.
• Ensure that the flue and seals are not damaged.
• The flue is sealed when assembled correctly, the components are
pushed fully home and secured.
• The flue is set at an angle of 3° or 52mm per metre length.
• Support the flue at approximately one metre intervals and at a
change of direction, use suitable brackets and fittings
(flue bracket 100mm part number: 7 716 191 177,
flue brackets 100mm x 6 part number: 7 716 191 178,
flue bracket 125mm part number: 7 716 191 179)
2m
1m
52mm
Fig. 35 Slope for condensate disposal