Worcester GREENSTAR HIGHFLOW 440CDi Instruction Manual page 12

Floor standing rsf gas-fired condensing combination boiler installation commissioning & servicing
Hide thumbs Also See for GREENSTAR HIGHFLOW 440CDi:
Table of Contents

Advertisement

Heating return
Hose
return
Stop
cock
Temporary
hose
10
WATER SYSTEMS & PIPEWORK
Water main
supply
Non
Non
return
return
valve
valve
Stop
cock
Test cock
WATER SYSTEMS & PIPEWORK
FILLING PRIMARY SYSTEMS:
• The CH sealed system must be filled using
a WRAS approved filling loop or comply
with the diagram opposite for system fill.
• The filling point must be at low level and
must never be a permanent direct fixing
to the mains water supply.
SHOWERS/BIDETS:
• If a shower head can be immersed in water
or comes closer than 25mm from the top
edge of a bath or shower tray spill over
level then an anti-siphon device must be
fitted to the shower hose.
• Bidets with direct hot & cold mains water
can be used (with the approval of the local
water authority) and must be the over rim
flushing type with shrouded outlets to
prevent the fitting of hand held sprays.
DOMESTIC HOT WATER:
• Taps and mixing valves must be capable
of sustaining a pressure up to 10 bar.
• Hot water temperature and flow rate are
affected by the size and insulation of
pipework making up the distribution system
and are controlled by the hot water tap
and the water main inlet pressure. A mixing
valve can be fitted if a more permanent
setting is required.
• If using more than one outlet at once
causes water flow starvation, fit flow
balancing valves or Ball-O-Fix valves to the
appropriate outlets.
INSTALLATION & SERVICING INSTRUCTIONS
8 716 115 219c (03.2010)