Floor standing oil fired condensing boiler conventional flue and room sealed flue
for sealed central heating systems with mains fed domestic hot water (16 pages)
Summary of Contents for Worcester Greenstar Highflow 440CDi
Page 1
THE APPLIANCE IS FOR USE WITH NATURAL GAS OR L.P.G. (Cat II 2H3P TYPE C13, C33 & C53) NATURAL GAS: GREENSTAR HIGHFLOW 440CDi GC NUMBER 47-406-24 GREENSTAR HIGHFLOW 550CDi GC NUMBER 47-406-25 LIQUID PETROLEUM GAS: GREENSTAR HIGHFLOW 440CDi GC NUMBER 47-406-26...
Page 2
CAREFULLY BEFORE OPERATING YOUR BOILER SERVICE: 08457 256206 THESE INSTRUCTIONS ARE APPLICABLE TO LITERATURE: 01905 752556 THE WORCESTER, BOSCH GROUP BOILER SALES: 01905 752640 MODEL(S) STATED ON THE FRONT COVER WEBSITE: www.worcester-bosch.co.uk OF THIS MANUAL ONLY AND MUST NOT BE USED WITH ANY OTHER MAKE OR MODEL OF BOILER.
Worcester, Bosch Group. The company prides itself on manufacturing boilers to the strictest quality control standards throughout every stage of production. Worcester, Bosch Group has led the field in innovative boiler design and performance for more than 40 years. This heritage means all products are of exceptional quality and proven reliability.
SAFETY PRECAUTIONS IF YOU SMELL GAS: DON'T SMOKE OR STRIKE MATCHES. DON'T TURN ELECTRICAL SWITCHES ON OR OFF. DO PUT OUT NAKED FLAMES. DO OPEN DOORS AND WINDOWS. DO KEEP PEOPLE AWAY FROM THE AREA AFFECTED. DO TURN OFF THE CONTROL VALVE AT THE METER. DO CALL YOUR GAS COMPANY.
GENERAL INFORMATION SERVICING The boiler must be serviced regularly by a competent, qualified person, such as a Worcester service engineer or alternatively a British Gas or other CORGI registered person. Always use original spares, to help maintain the economy, safety and reliability of the boiler and to have the Service Record completed in the Benchmark checklist.
GENERAL NOTES To get the best from your boiler please read CLEARANCES - SERVICE these instructions carefully. Your installer will have provided adequate SEALED HEATING SYSTEMS space around the boiler for safety and servicing This boiler is fitted to a sealed heating system access.
Page 7
GENERAL NOTES BOILER CLEARANCES - UNVENTILATED COMPARTMENT The diagram opposite shows the minimum space required to install and service the boiler 800mm inside an unventilated compartment. 800mm * Space required for unventilated areas with 50mm a removable door or panel, but 600mm to a fixed surface for servicing.
CONTROLS A - MASTER SWITCH FOR ON/OFF B - MAINS ON/OFF INDICATOR + FAULT DIAGNOSTIC LIGHT C - CENTRAL HEATING TEMPERATURE CONTROL D - BURNER ON INDICATOR LIGHT (GREEN) E - FAULT RESET BUTTON F - SERVICE BUTTON G - DOMESTIC HOT WATER TEMPERATURE CONTROL H - ECO BUTTON I - SYSTEM PRESSURE GAUGE J - POSITION FOR OPTIONAL PROGRAMMER...
Page 9
CONTROLS TO ACCESS THE CONTROLS Pull the centre top of the cover panel to allow the cover to open. TO ACCESS THE FILLING LOOP CONTROLS CONNECTION COVER Pull the front panel away from the boiler and lift up. PULL LIFT Filling Loop connection...
OPERATING THE APPLIANCE SWITCHING THE APPLIANCE ON/OFF Switching on Switch on the appliance by pressing the master switch. The indicator light shows blue • The boiler runs for 15 minutes at minimum heating output to fill the condensate trap, the display (K) alternates between ‘-II-’...
OPERATING THE APPLIANCE FROST PROTECTION If heating is NOT required: Leave master switch on. Turn the central heating temperature control to If the temperature falls to 5 °C inside the boiler, the boiler will fire to prevent the possibility of freezing. Add a suitable anti-freeze fluid to the water in the central heating system.
OPERATING THE APPLIANCE FAULT CONDITION In the unlikely event of a fault occurring while the appliance is in operation: The reset button will flash once per second and the mains indicator (blue light) will flash also. The display shows a fault code. To reset boiler press the reset button.
If your Greenstar gas-fired boiler should fail to operate correctly or requires servicing please contact the Worcester, Bosch Group Service Department (see inside front cover for details). Details of the boiler including the Gas Council number can be found under the controls cover flap on the boiler.
FAULT FINDING This table gives information on basic operating system problems. In the unlikely event of a boiler fault please read the following page thoroughly before contacting Worcester, Bosch Group. PROBLEM CAUSE REMEDY Desired room Thermostatic radiator Increase thermostatic radiator...
FAULT OR BREAKDOWN This boiler is supported in the UK and Eire by Worcester, Bosch Group. Specially trained, Worcester, Bosch Group Service Engineers are available to attend a breakdown occurring on this boiler. No charge will be made for parts and/or labour providing: An boiler fault is found and the boiler has been installed within the past 24 months.
TIPS ON ENERGY SAVING HEATING ECONOMICALLY The boiler is designed to provide a high level of comfort while keeping gas consumption and the resulting environmental effect as low as possible. The gas supply to the burner is controlled according to the level of demand for heat. The boiler continues to operate with a low flame if the demand for heat reduces.
Page 17
TIPS ON ENERGY SAVING DRAUGHTS Try to ensure that draughts around doors, windows, letterboxes and keyholes etc. are reduced by using a suitable draught excluder. Warning - Do not block or seal any air vents that are installed to ensure the central heating boiler operates safely. ROOM THERMOSTATS Reducing the setting of the room thermostat by 1°C can reduce fuel consumption by up to 10%.
YOUR GUARANTEE This boiler is guaranteed against faulty material or workmanship for a period of 2 years from the date of installation subject to the following terms and conditions: Your Guarantee Registration Card must be returned within 30 days for the second year of your guarantee to become valid.
GUARANTEE REGISTRATION You should complete and return the postpaid Guarantee Registration Card within 30 days of purchase. Returning the card will register you as the owner of your new Greenstar boiler and will assist us in maintaining an effective and efficient customer service by establishing a reference and permanent record for your boiler.
Page 20
Dedicated to heating comfort Worcester, Bosch Group Cotswold Way, Warndon, Worcester WR4 9SW Tel. 01905 754624 Fax. 01905 754619 Worcester, Bosch Group is a brand name of Bosch Thermotechnology Ltd. worcester-bosch.co.uk 8 716 115 220a (07.2008) Supplied By www.heating spares.co Tel. 0161 620 6677...
Need help?
Do you have a question about the Greenstar Highflow 440CDi and is the answer not in the manual?