Floor standing oil fired condensing boiler conventional flue and room sealed flue
for sealed central heating systems with mains fed domestic hot water (16 pages)
Greenstar i system compact series wall hung rsf gas fired condensing system boiler (68 pages)
Summary of Contents for Worcester GREENSTAR HEATSLAVE II SERIES
Page 1
USER INSTRUCTIONS & CUSTOMER CARE GUIDE FLOOR STANDING OIL FIRED CONDENSING BOILER CONVENTIONAL FLUE & ROOM SEALED FLUE GREENSTAR HEATSLAVE II 12/18, 18/25 & 25/32 FOR SEALED CENTRAL HEATING SYSTEMS WITH MAINS FED DOMESTIC HOT WATER THE BOILER IS FOR USE WITH KEROSENE (28 SECOND OIL) ONLY...
0844 892 3366 OPERATING YOUR BOILER SERVICE: 0844 892 3000 THESE INSTRUCTIONS ARE SERVICE (EIRE) 01494 0099 APPLICABLE TO THE WORCESTER, BOSCH GROUP BOILER MODEL(S) LITERATURE: 0844 892 9800 STATED ON THE FRONT COVER OF SALES: 01905 752640 THIS MANUAL ONLY AND MUST NOT...
YOUR GUARANTEE AND REGISTRATION Dedicated to heating comfort Thank you for purchasing a Greenstar oil fired condensing boiler from Worcester, Bosch Group. The company prides itself on manufacturing boilers to the strictest quality control standards throughout every stage of production.
SAFETY PRECAUTIONS OIL FUMES OR LEAKS FROM THE BOILER: ✔ Extinguish any naked flames. ✔ Open windows and doors. ✔ Switch off the boiler electricity supply. ✔ Isolate the fuel supply to the boiler. ✔ Contact installer/service engineer. IMPORTANT: This boiler must only be operated by a responsible adult who has been instructed in, understands and is aware of the boiler’s operating conditions and effects.
CONTROLS A Spanner/return button B Reset button C ECO button D Boiler LCD display E Central heating temperature control F Scroll up button G OK - Select/confirmation button H Scroll down button Demand/fault indicator (blue) J Position for optional programmer K Hot water temperature control L Diagnostic port (service engineer) M System pressure guage...
Page 6
CONTROLS DISPLAY SYMBOLS: SCREEN DISPLAY DESCRIPTION EXPLANATION All possible screen All possible screen symbols are symbols (including displayed briefly during start up. The greyed out symbols) greyed out symbols are not required for the operation of this appliance. Numerical display Displays a temperature setting or boiler status code.
OPERATING THE BOILER SWITCHING THE BOILER ON/OFF: 4 To switch on the boiler; turn on the water, oil and electricity supply to the boiler. 4 Check the programmer/timer is correct and is set to ON. 4 Set the room thermostat to the desired setting. 4 Open and set thermostatic radiator valves as required.
OPERATING THE BOILER SETTING THE HOT WATER TEMPERATURE: The hot water temperature control knob sets the temperature of the heat store. A high setting will give a higher hot water temperature and greater quantities of hot water. 1. Turn the hot water temperature control knob to the desired level between 1 and 8, this will be shown on the digital display.
OPERATING THE BOILER DOMESTIC HOT WATER ECO MODE: Eco mode is an energy saving feature which alters the cycling function of the burner for heating the heat store tank. In normal operation the burner will fire more frequently between demands in order to maintain a stored temperature close to the hot water set point you have entered.
In some cases a Blocking error has a defined time duration prior to changing to a Locking condition. If the fault remains and cannot be cleared by pressing the reset button, contact Worcester, Bosch Group for assistance on 0844 892 3000.
OPERATING THE BOILER SYSTEM PRESSURE: This boiler is fitted to a sealed heating system which is pre-pressurised. Your installer will advise you of the minimum and maximum pressure indicated on the pressure gauge. 4 Check regularly that the pressure is maintained. Optimum system pressure when your boiler is cold (area A) and the pump is off.
FAULT FINDING Problem Cause Remedy Desired room temperature Thermostatic radiator Increase thermostatic is not reached valve(s) set too low radiator valve setting(s) Room thermostat set too Increase room thermostat setting Temperature control for Increase CH flow CH flow on boiler set too temperature control setting Air trapped in heating...
OFTEC engineer or other suitably qualified person. If you would like to know more about servicing options from Worcester, Bosch Group, please visit worcester-bosch.co.uk. Please tick the appropriate box on your warranty registration card for further details of the Worcester, Bosch Group Service Contract .
SERVICING SERVICING: You must have the boiler regularly serviced by a competent, qualified OFTEC registered engineer using approved spares, to help maintain the economy, safety and reliability of the boiler. The boiler should be serviced once each year after installation unless the installation conditions and usage demand more frequent services.
VENTILATION INFORMATION BOILER LOCATION: **The boiler can be installed under a worktop as long as: 4 The worktop above the boiler is easily removable for maintenance. 4 There is at least 10mm clearance above the boiler. 4 The front of the boiler is not enclosed. VENTILATION: Air vents must be functional at all times and the air supply must not be restricted or contaminated.
Page 16
VENTILATION INFORMATION Conventional flue boilers require an adequate supply of fresh air which must be delivered to the boiler for combustion purposes through a permanent inlet, such as an air brick, into the area where the boiler is situated. If a cupboard or compartment which is to be used for storage or airing is built around the boiler after installation there must be a non-combustible partition around the boiler.
GENERAL NOTES To get the best from your boiler. please read these instructions carefully. CENTRAL HEATING SYSTEMS During the first few hours of operation of the central heating system, check that all radiators are being heated at an even rate. If the top of a radiator is at a lower temperature than the bottom then it should be vented by releasing air through the venting screw at the top of the radiator.
TIPS ON ENERGY SAVING Room thermostats: Reducing the setting of the room thermostat by 1°C can reduce fuel consumption by up to 10%. New control systems: Upgrade your heating control system with the latest equipment available. The minimum level of control for a heating system is a programmer, interlocking room thermostat and thermostatic radiator valves.
FAULT OR BREAKDOWN BOILER DATA LABEL This boiler is supported in mainland UK by Worcester, Bosch Group, part of Bosch The data label can be found on the inside of the Thermotechnology Ltd. right hand side panel. Specialist trained, Worcester, Bosch Group Service...
4 This guarantee applies only to equipment purchased and installed in mainland UK. This guarantee is given in addition to all your normal statutory rights. Worcester, Bosch Group is a brand name of Bosch Thermotechnology Ltd. GREENSTAR HEATSLAVE II 12/18, 18/25 & 25/32 GUARANTEE REGISTRATION 6 720 805 211a (07.2013)