FLUE TERMINAL PLUME MANAGEMENT

A
B
C
A
B
±80°
C
B
FLUE TERMINAL PLUME
MANAGEMENT
The flue discharge can be redirected allowing
some plume management control, alternatively,
a complete plume management system can be
fitted to the flue terminal.
Redirecting the flue discharge:
Important: should you wish to use the
plume deflector please use the additional
grease enclosed to ensure that an
adequate seal is retained.
1
Remove screws (A) and terminal end (B).
2
Spread the extra grease supplied into
the groove that runs around the terminal
outlet (C) to ensure a good seal is retained.
3
Rotate the detached end section (B) to
plume deflecting position, as shown and
refit using screws (A).
4
Loosen screws (D) and rotate the terminal
end (B & C) to redirect the plume.
DO NOT rotate the complete flue terminal
assembly.
Retighten screws (D) to secure in the
required position.
NOTE: the flue terminal outlet has built-in
stops to limit rotation for horizontal fluing
to allow condensate to run back into the
boiler for safe disposal. Do not attempt to
force beyond the limit stops.