Section 2

Location of Ice Machine

The location selected for the ice machine must meet the
following criteria. If any of these criteria are not met,
select another location.
The ice machine may be built into a cabinet, however
the location must allow removal of the ice machine
for cleaning and servicing. Service diagnostics are
performed from the top of the ice machine. Refer to
Minimum Cut-Out for Built-In Installations on page
2-2.
The location must be free of airborne and other
contaminants.
The air temperature must be at least 50°F (10°C), but
must not exceed 110°F (43°C).
The location must not be near heat-generating
equipment.
The location must not obstruct air flow through the
condenser (airflow is in and out the front of the ice
machine).
The location must allow enough clearance for water,
drain and electrical connections at the rear of the ice
machine.
The ice machine may be installed outside.
The ice machine must be protected if it will be
subjected to ambient temperatures below 32°F
(0°C). Component failure caused by exposure to
freezing temperatures is not covered by the
warranty.
See
Winterization".
Part Number 000001590
2940 Hwy 14 W, Rochester, MN 55901
! Caution
"Removal
from
Service/

CLEARANCES

Top/Sides
Back
Front
*The ice machine may be built into a cabinet. There is no minimum clearance
requirement for the top or sides of the ice machine. The listed values are
recommended for efficient operation and servicing only.
Installation Instructions
5" (12.7 cm)*
5" (12.7 cm)
24" (60.9 cm)
2-3