Total Restaurant Supply - https://totalsupply1.com - Toll Free 1-800-944-9304 - Local 507-288-9454
Maintenance
Water Trough
1. Depress tabs on right and left side of the water
trough.
2. Allow front of water trough to drop as you pull
forward to disengage the rear pins.
Water Trough Removal
4-8
2940 Hwy 14 W, Rochester, MN 55901
Spray Bar, Water Pump and Hose
Disconnect the electric power to the ice machine at
the electric service switch box and turn off the water
supply before proceeding.
1. Remove spray bar clamp and spray bar.
2. Grasp pump and pull straight down until water pump
disengages and electrical connector is visible.
3. Disconnect the electrical connector.
4. Remove the water pump from ice machine.
5. Remove clamp from hose to remove from pump.
6. Do not soak the water pump in cleaner or sanitizer.
Wipe the pump and ice machine base clean.
!
Warning
REMOVE CLAMP
REMOVE CLAMP
Part Number 000001590