Total Restaurant Supply - https://totalsupply1.com - Toll Free 1-800-944-9304 - Local 507-288-9454
Maintenance
Top Cover
1. Remove two back screws.
!
Disconnect the electrical power to the ice machine
at the electrical disconnect before proceeding.
2. Slide back and lift cover off.
1
2
4-6
2940 Hwy 14 W, Rochester, MN 55901
Warning
Water Shutters
The water shutter is designed to keep the spraying water
from escaping the evaporator compartment.
To remove just the water shutters:
1. Grasp one end of the water shutter and lift up.
2. Pivot water shutter and disengage remaining end.
3. To re-install into ice machine, grasp one end of the
water shutters, install one end, pivot the opposite
end and pull down into position. Make sure tabs are
secure in grooves.
To remove water shutter assembly:
1. Slide evaporator bucket forward 1/2" (13 mm).
2. Lift shutter assembly straight up.
Shutter
Assembly
!
Removing the water shutters while the water pump
is running will allow water to spray from ice
machine. Disconnect the electrical power to the ice
machine at the electric service switch box and turn
off the water supply.
Section 4
Grasp
Water
Shutters
Here
Water
Shutters
Warning
Part Number 000001590