TCM Error Messages (Continued)
Table 5-2
Error
Illegal ESS ID
Disk Full
Target Disk Full
Hex file is READ ONLY
Error opening the file xxx with
write access
Failure creating binary file
Hex File To load is missing or
invalid
Could not locate MK4000
name in TCM.ini file
Incorrect disk sizes in TCM.ini
file
INVALID DIRECTORY
One of the disk sizes is one
sector in size
INVALID VOLUME NAME
Corrupt TCM.INI file! (Invalid
value of VolumeDivisor)
Invalid version of TCM script
file
Corrupt or missing TCM.ini
file
FAILED CONNECTION TO
COM PORT (Could not get
status)
FAILED CONNECTION TO
TERMINAL (Terminal Not
Connected Properly/Terminal
Not Ready to Receive)
In the Build ESSID Partition window, no ESS ID was entered or the ESS ID
entered was illegal.
TCM failed to create Hex image file at the selected path. Check available disk
space.
Build process failed because TCM failed to add file to the image of a disk volume.
Remove some files or increase the disk size.
The Hex image file to be created exists and is read-only. Delete the existing file or
change its attribute.
TCM could not open file xxx with write access. Check if file is in use.
TCM failed to open/create an intermediate binary file.
In Load Terminal window, the file selected to load has invalid status.
While loading the Script Properties window, TCM could not find the TCM.ini
section corresponding to the MK4000 type specified by the current opening script.
Either TCM.ini or the script file is invalid.
The total disk size specified in the script does not match the total disk size defined
in the corresponding TCM.ini section. Check if the script is corrupt or the TCM.ini
has changed after the script was created.
In Script Properties window, the selected System File Path is not a valid directory.
In Script Properties window, one of the disks is too small (one sector in size). This
may cause problem while building images, especially when cushion is enabled.
Increase the disk size.
In Script Properties window, one of the volume labels is not valid.
The VolumeDivisor entry is missing or invalid in the TCM.ini. Reinstall TCM or
recover TCM.ini.
The TCM script was not created by this version of TCM.
TCM could not find TCM.ini file.
While downloading images to MK4000, TCM failed to connect to the selected
COM port. Check if the COM port is free and is properly configured.
While downloading images, TCM failed to connect to the MK4000. Check if the
correct flow control protocol is selected and the MK4000 is properly connected
and is in a listening state.