Calibrating the Screen
Use the
screen to align the touch screen:
Calibration
Remove and restore power to the MK4000 to reboot.
1.
Calibration Screen
Figure 5-12
NOTE To access the Calibration screen from the Windows CE Control Panel, tap Start > Settings > Control
Panel. Double-tap the Stylus icon, tap the Calibration tab, and tap the Recalibrate button. The
Calibration screen appears.
Carefully press and briefly hold the stylus tip on the center of the
2.
procedure as the target moves and stops at different locations on the screen.
The
3.
Confirm Calibration
MK4000 returns to the Calibration screen.
TCM Error Messages
TCM validates the cells in the partition table when you click the Execute button. Cells highlighted in red contain an
error. Partition loading is disabled until all errors are corrected.
TCM Error Messages
Table 5-2
Error
Failed to build images: flash
file system DLL not loaded!
Failure finding directory xxx
Failure creating volume
Failure adding system file to
image
INVALID PATH
Nothing Selected To Build
screen displays. Tap the screen to accept the settings, or wait 30 seconds and the
TCM could not load the DLL required to build images for the targeting flash file
system. Reinstall TCM or recover the DLL.
Building process failed because directory xxx was not found.
Building process failed because a certain disk volume could not be created.
Build process failed because TCM failed to add a certain system file to the disk
image.
The path for the image file to build is not valid.
In the Config Build window, no item is selected to build.
Application Deployment 5 - 15
screen target. Repeat the
Calibration
Description/Solution