Planet Networking & Communication IAP-2000PS User Manual

Industrial 802.11n wireless poe access point

Advertisement

Quick Links

Advertisement

Table of Contents
loading

Summary of Contents for Planet Networking & Communication IAP-2000PS

  • Page 2: Federal Communication Commission Interference Statement

    Copyright Copyright  2012 by PLANET Technology Corp. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise, without the prior written permission of PLANET.
  • Page 3 Federal Communication Commission (FCC) Radiation Exposure Statement This equipment complies with FCC radiation exposure set forth for an uncontrolled environment. In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, human proximity to the antenna shall not be less than 20 cm (8 inches) during normal operation. CE mark Warning This is a class B device, in a domestic environment;...
  • Page 4 Do not dispose of WEEE as unsorted municipal waste and have to collect such WEEE separately. Revision User’s Manual for PLANET Industrial 802.11n PoE Wireless Access Point Model: IAP-2000PE / IAP-2000PS / IAP-2001PE Rev: 1.2 (February, 2012) Part No. EM-IAP200x_v1.2 (2081-E50230-001)
  • Page 5: Table Of Contents

    CONTENTS Chapter 1. INTRODUCTION ..................6 1.1. Package Contents ....................... 6 1.2. Product Features......................6 1.3. Product Specification ....................7 Chapter 2. INSTALLATION ..................9 2.1. Hardware Description ....................9 2.1.1. Physical Dimension......................9 2.1.2. Front Panel ........................10 2.1.3. LED Indicators ........................ 11 2.1.4.
  • Page 6 4.6.2. Port Setting ........................65 4.6.3. VLAN Setting ........................65 4.6.4. MAC Address Table......................67 4.7. System Tools ......................67 4.7.1. PoE Configuration ......................68 4.7.2. IPv6 Ping......................... 70 4.7.3. Upload Firmware......................71 4.7.4. Settings Management ..................... 71 4.7.5. Reboot ..........................72 4.7.6.
  • Page 7: Chapter 1. Introduction

    User’s Manual of IAP-200x Series Chapter 1. INTRODUCTION The PLANET 802.11n Industrial Access Point Series – IAP-2000PS / IAP-2000PE / IAP-2001PE are industrial grade multiple 10/100Mbps ports wireless Access Point. The descriptions of these models are listed as below: Model...
  • Page 8: Product Specification

    -10 to 60 Degree C Operating Temperature  Redundant Power Design  IP-30 Aluminum case protection / DIN Rail and Wall-mount Design 1.3. Product Specification Model IAP-2000PS IAP-2000PE IAP-2001PE Hardware Specification 4 x 10/100Base-TX Auto-Negotiation 10/100Base-TX Ports Auto MDI / MDI-X IEEE 802.3af PoE Ports...
  • Page 9 User’s Manual of IAP-200x Series 11n 40MHz MCS7: -70dbm Wireless Management Features Access Point Wireless Mode 20MHz / 40MHz Channel Width 64 bit / 128 bit WEP WPA / WPA2 Data Encryption Security WPA-PSK / WPA2 / WPA2-PSK 802.1x Network Access Control Management Web-based Configuration Wireless Isolation...
  • Page 10: Chapter 2. Installation

    User’s Manual of IAP-200x Series Chapter 2. INSTALLATION 2.1. Hardware Description 2.1.1. Physical Dimension  IAP-200x series Industrial Access Point dimension (D x W x H) : 135mm x 87.8mm x 56mm Figure 2-1 IAP-200xPx diagram...
  • Page 11: Front Panel

    User’s Manual of IAP-200x Series 2.1.2. Front Panel Figure 2-2 & 2-3 & 2-4 show the front panels of Industrial Access Points Figure 2-2 IAP-2000PS Figure 2-3 IAP-2000PE Figure 2-4 IAP-2001PE ■ Reset Button In the bottom of the front panel, the reset button is designed for reset the Industrial Access Point to the factory default settings.
  • Page 12: Led Indicators

    User’s Manual of IAP-200x Series The following is the summary table of Reset button functions: Reset Button Pressed and Released Description About 1~3 second Reboot the Industrial AP Reset the Industrial AP to the Factory Default configuration. The Industrial AP will then reboot and load the default settings as below: Over 5 seconds 。...
  • Page 13: Upper Panel

    User’s Manual of IAP-200x Series 2.1.4. Upper Panel Figure 2-6 IAP-2000PS Upper Panel Figure 2-7 IAP-2000PE / IAP-2001PE Upper Panel 2.2. Hardware Installation This section describes how to install your Industrial access point and make connection to it. Please read the following topics and perform the procedures in the order being presented.
  • Page 14: Din-Rail Mounting

    User’s Manual of IAP-200x Series the Industrial access point, please refer to DIN-Rail Mounting section for DIN-Rail installation. If users want to wall mount the Industrial access point, please refer to Wall Mount Plate Mounting section for wall mount plate installation. To hang the Industrial access point on the DIN-Rail track or wall.
  • Page 15 User’s Manual of IAP-200x Series Step 1: Screw the DIN-Rail on the Industrial Access Point. Figure 2-8 Step 2: Lightly press the button of DIN-Rail into the track. Figure 2-9 -14-...
  • Page 16 User’s Manual of IAP-200x Series Step 3: Check the DIN-Rail is tightly on the track. Figure 2-10 Please refer to the following procedures to remove the Industrial Access Point from the track. Step 5: Lightly press the button of DIN-Rail for remove it from the track. Figure 2-11 -15-...
  • Page 17: Wall Mount Plate Mounting

    User’s Manual of IAP-200x Series 2.2.3. Wall Mount Plate Mounting To install the Industrial Access Point on the wall, please follow the instructions below. Step 1: Remove the DIN-Rail from the Industrial Access Point. Use the screwdriver to loose the screws and remove the DIN-Rail.
  • Page 18 V2 - V2 + Figure 2-13 The Top Panel of IAP-2000PE / IAP-2001PE V1- V1 + V2 - V2 + Figure 2-14 The Top Panel of IAP-2000PS 2. Tighten the wire-clamp screws for preventing the wires from loosing. Power 1 Fault...
  • Page 19: Cabling

    The 10/100Mbps RJ-45 ports come with Auto-Negotiation capability. Users only need to plug in working network device into one of the 10/100Mbps RJ-45 ports. The IAP-2000PS / IAP-2000PE series will automatically run in 10Mbps or 100Mbps after the negotiation with the connected device. The IAP-2001PE has one 100Base-FX SFP interface (Optional Multi-mode / Single-mode 100Base-FX SFP module) ...
  • Page 20: Removing The Module

    User’s Manual of IAP-200x Series Figure 2-16 Plug in the SFP transceiver Before connect the other switches, workstation or Media Converter, Make sure both side of the SFP transceiver are with the same media type or WDM pair, for example: 100Base-FX to 100Base-FX, 100Base-BX20-U to 100Base-BX20-D.
  • Page 21 User’s Manual of IAP-200x Series Figure 2-17 Pull Out the SFP transceiver Never pull out the module without pull the handle or the push bolts on the module. Direct pull out the module with violent could damage the module and SFP module slot of the device.
  • Page 22: Chapter 3. User Management Interface

    User’s Manual of IAP-200x Series Chapter 3. USER MANAGEMENT INTERFACE 3.1. Overview The Industrial Access Point provides a user-friendly, Web interface. Via this interface, you can perform various device configuration and management activities, including:  System  Power over Ethernet ...
  • Page 23 User’s Manual of IAP-200x Series Figure 3-1 IP Management Diagram The IAP-200x Series need to be configured through the Ethernet connection, so the manager PC must be on the same IP subnet address. The default setting of the DHCP server in the IAP-200x Series is disabled. If your PC obtains the IP address from other devices, please manually configure the correct IP address as 192.168.1.xxx, xxx is from 2 to 254.
  • Page 24: Planet Smart Discovery Utility

    User’s Manual of IAP-200x Series 3. After entering the user name and password, you will see the main screen based on IAP-2000PE Figure 3-3 for example. Figure 3-3 Main Screen of IAP-2000PE Web UI For security reason, please change and remember the new password after first setup. Only the command in lowercase letter is accepted under WEB interface.
  • Page 25 User’s Manual of IAP-200x Series Figure 3-5 PLANET Smart Discovery Utility Snapshot If there are two LAN cards or above in the same administrator PC, please choose the different LAN card via the “Select Adapter” field. Click “Refresh” button to renew the list of the PLANET industrial devices connected in the network. The screen is shown as follow.
  • Page 26 User’s Manual of IAP-200x Series Update All: use current setting on every device in the list. The same functions mentioned above can be found in “Option” tools bar as well. Click the “Control Packet Force Broadcast” function, and it will assign new setting value to the switch under different IP subnet address.
  • Page 27: Chapter 4. Web Configuration

    User’s Manual of IAP-200x Series Chapter 4. WEB CONFIGURATION The Industrial Access Point provides Web interface for configuration and make the Industrial Access Point operate more effectively - Users can configure through the Web Browser and the network administrator can manage and monitor the Industrial Access Point from the local LAN.
  • Page 28: Web Panel

    User’s Manual of IAP-200x Series 4.2. Web Panel On the left of the web management page, the active panel displays the link status of management port and PoE ports. Figure 4-2 Left Side of the Main Menu Screen (Light Indicators) Please refer the section 2.1.3 to find the descriptions of each LED.
  • Page 29: System

    User’s Manual of IAP-200x Series 4.3. System The submenus of System option is shown below: Figure 4-3 4.3.1. Operation Mode Select the operation mode you want to use, and then click Apply button to make the changes take effect. Figure 4-4 -28-...
  • Page 30: Management

    User’s Manual of IAP-200x Series  Bridge: The Bridge mode allows that all Ethernet and wireless interfaces are bridged into a single Bridge interface.  Wireless ISP: The Wireless ISP mode allows that the wireless interface is treated as WAN port, and the Ethernet ports are LAN ports.
  • Page 31: Snmp Configuration

    User’s Manual of IAP-200x Series  Password: Enter the password of the administrator in the field. Maximum length: 16 characters. NTP Settings Object Description Display the current date and time.  Current Time: Click Sync with host, the current time is synchronized by your PC which is connected to Router.
  • Page 32 User’s Manual of IAP-200x Series Figure 4-6 The page includes the following fields: SNMP Configuration Object Description  Mode : Indicates the SNMP mode operation. Possible modes are:  Enabled: Enable SNMP mode operation.  Disabled: Disable SNMP mode operation. ...
  • Page 33: Status

    User’s Manual of IAP-200x Series The allowed string length is 0 to 255.  System Location : The physical location of this node (e.g., telephone closet, 3rd floor).  Allowed IP to Access: Indicates the host can access the AP from SNMP interface that the host IP address matched the entry.
  • Page 34 User’s Manual of IAP-200x Series Figure 4-7 The page includes the following fields: Object Description  Firmware Version : Displays the Industrial AP’s firmware version.  System Up Time: The period of time the device has been operational.  Operation Mode: Displays the current operation mode.
  • Page 35: Network Settings

    User’s Manual of IAP-200x Series 4.4. Network Settings The submenus of Network Settings option is shown below: Figure 4-8 4.4.1. LAN Users can configure the network settings and the parameters as you wish. -34-...
  • Page 36 User’s Manual of IAP-200x Series Figure 4-9 The page includes the following fields: LAN Interface Setup Object Description  IP Address: Enter the IP address of LAN port or reset it in dotted-decimal notation. Factory default : 192.168.1.1  Subnet Mask: Enter the subnet mask of LAN port.
  • Page 37 User’s Manual of IAP-200x Series  DHCP Type: You can select Server or Disable.  Disable: If you select Disable, the DHCP service of LAN side is disabled.  Server: After selecting Server, the DHCP server is enabled on LAN side.
  • Page 38: Dhcp Clients

    User’s Manual of IAP-200x Series The subnet masks of all the hosts in LAN must be set to be the same as the subnet mask in this page. 4.4.2. DHCP Clients The administrator can check the user list of the DHCP server in this page. The table window shows the active clients with their Hostname, MAC address, assigned IP address, and time expired information.
  • Page 39: Wireless Settings

    User’s Manual of IAP-200x Series represented as eight fields of up to four hexadecimal digits with a colon separates each field (:). For example, 'fe80::215:c5ff:fe03:4dc7'. The symbol '::' is a special syntax that can be used as a shorthand way of representing multiple 16-bit groups of contiguous zeros;...
  • Page 40 User’s Manual of IAP-200x Series Figure 4-14-1 The page includes the following fields: Wireless Network Object Description  Radio On/Off: Click Wireless OFF button to turn off wireless RF radio. Click Wireless ON button to turn on wireless RF radio. ...
  • Page 41 User’s Manual of IAP-200x Series  Multiple SSID There are 5 multiple SSIDs. Enter their descriptive names that you want to 1/2/3/4/5: use. Please enable VLAN function (section 4.6.3) first before using Multiple SSID.  Broadcast Network Select Enable to allow the SSID broadcast on the network, so that the STA Name (SSID): can find it.
  • Page 42: Advanced

    User’s Manual of IAP-200x Series HT Physical Mode Object Description  Operation Mode: Select Mixed Mode or Green Field for 11n mode.  Channel Bandwidth: Select the operating channel width 20 MHz or 20/40 MHz.  Guard Interval: Select “Long” or “Auto”. Guard intervals are used to ensure that distinct transmissions do not interfere with one another.
  • Page 43 User’s Manual of IAP-200x Series Figure 4-15 Advanced Wireless Object Description  BG Protection Mode: It provides 3 options, including Auto, On, and Off. The B/G protection technology is CTS-To-Self. It will try to reserve the throughput for 11g clients from 11b clients connecting to the device as AP mode.
  • Page 44 User’s Manual of IAP-200x Series the clients that multicast and broadcast packets buffered at the AP will be transmitted immediately after the transmission of this beacon frame. You can change the value from 1 to 255. The AP will check the buffered data according to this value.
  • Page 45: Security

    User’s Manual of IAP-200x Series Wi-Fi Multimedia Object Description  WMM Capable: Enable or disable WMM. After enabling WMM, the wireless AP can process different types of wireless data according to their priority levels.  APSD Capable: Enable or disable APSD. After enabling APSD, it can decrease the consumption of the power supply device.
  • Page 46 User’s Manual of IAP-200x Series Figure 4-16 Select SSID Object Description  SSID choice: Select SSID in the drop-down list.  Security Mode: There are 11 options, including:  Disable  WPA2  OPEN  WPA2-PSK  SHARED  WPAPSKWPA2PSK ...
  • Page 47 User’s Manual of IAP-200x Series B. OPEN / SHARED If you set Security Mode to “OPEN” or “SHARED”, please fill in the related configurations at below. Figure 4-17 OPEN-WEP Object Description  Default Key Specify a Key number for effective. ...
  • Page 48 User’s Manual of IAP-200x Series C. WPA-PSK Figure 4-18 WPA-PSK The page includes the following fields: Object Description  WPA Algorithms : Select TKIP, AES or TKIPAES for WPA algorithms. Set 8-bit to 64-bit key in ASCII characters.  Pass phrase : You may select to select Passphrase (alphanumeric format) or Hexadecimal Digits (in the “A-F”, “a-f”...
  • Page 49 User’s Manual of IAP-200x Series D. WPA Figure 4-19 WPA-RADIUS The page includes the following fields: Object Description  WPA Algorithms Select TKIP, AES or TKIPAES for WPA algorithms.  Key Renewal Interval Please fill in a number for Group Key Renewal interval time. ...
  • Page 50 User’s Manual of IAP-200x Series timeout interval unit is second and must be larger than 60. Enter the idle timeout in the column.  Idle Timeout E. WPA2-PSK Figure 4-20 WPA2-PSK The page includes the following fields: Object Description  WPA Algorithms : Select TKIP, AES or TKIPAES for WPA algorithms.
  • Page 51 User’s Manual of IAP-200x Series F. WPA2 Figure 4-21 WPA2-RADIUS The page includes the following fields: Object Description  WPA Algorithms Select TKIP, AES or TKIPAES for WPA algorithms.  Key Renewal Interval Please fill in a number for Group Key Renewal interval time. Only valid in WPA2 security.
  • Page 52 User’s Manual of IAP-200x Series enables secure fast roaming without noticeable signal latency. Enter the password that the Wireless AP shares with the RADIUS Server.  Shared Secret Session timeout interval is for 802.1x re-authentication setting. Set to zero  Session Timeout to disable 802.1x re-authentication service for each session.
  • Page 53 User’s Manual of IAP-200x Series F. 802.1X Figure 4-22 802.1X The page includes the following fields: 802.1X WEP Object Description  Enable or Disable WEP encryption. -52-...
  • Page 54 User’s Manual of IAP-200x Series Radius Server Object Description  IP Address: Enter the IP address of Radius Server.  Port: The default port of the RADIUS server for authentication is 1812. You need not change this value unless your network administrator instructs you to do so with additional information.
  • Page 55: Wps

    User’s Manual of IAP-200x Series 4.5.4. WPS Users can enable, disable, and configure the WPS (Wi-Fi Protected Setup) function in this page. Figure 4-23 WPS Config Object Description  WPS: You can enable or disable the WPS function in this field. WPS Summary It displays the WPS information, such as WPS Current Status, WPS Configured, and WPS SSID.
  • Page 56 User’s Manual of IAP-200x Series WPS Progress Object Description  WPS mode: There are two way for you to enable WPS function:  PBC - You can use a push button configuration (PBC) on the Wi-Fi router.  PIN - If there is no button, enter a 4- or 8-digit PIN code. Each STA supporting WPS comes with a hard-coded PIN code.
  • Page 57 User’s Manual of IAP-200x Series Step 1 & 2 should process within two minutes. Step 3: Wait for a while until the connection established to complete the WPS configuration. By PIN If the new device supports Wi-Fi Protected Setup and the PIN method, you can add it to the network by PIN with the following two methods.
  • Page 58 User’s Manual of IAP-200x Series Figure 4-26 WPS – PIN of AP Step 2: For the configuration of the wireless adapter, please choose the option that you want to enter the PIN of the AP in the configuration utility of the Wireless adapter, and enter it into the field. Then click Next. Step 3: You will see the WPS Current Status is “Configured”...
  • Page 59: Wds

    User’s Manual of IAP-200x Series The WPS function cannot be configured if the Wireless Function of the AP is disabled. Please make sure the Wireless Function is enabled before configuring the WPS. 4.5.5. WDS WDS (Wireless Distribution System) allows access points to communicate with one another wirelessly in a standardized way.
  • Page 60 User’s Manual of IAP-200x Series WDS Mode: There are four options, including Disable, Lazy Mode, Bridge Mode, and Repeater Mode.  Disable Select Disable to disable the WDS mode.  Lazy Mode Figure 4-19 Object Description  WDS Mode: Select Lazy Mode. The IAP-200X WDS Lazy mode is allowed the other IAP-200X WDS bridge / repeater mode link automatically.
  • Page 61 User’s Manual of IAP-200x Series  Bridge Mode/ Repeater Mode Figure 4-20 Object Description  WDS Mode: Select Bridge Mode or Repeater Mode.  Phy Mode: It provides 4 options, including CCK, OFDM, HTMIX, and GREENFIELD.  Encryp Type: It provides 4 options, including None, WEP, TKIP, and AES. ...
  • Page 62 User’s Manual of IAP-200x Series Repeater Mode Configuration In the Repeater mode, you can use the wireless AP to connect to the primary AP, for extending the wireless coverage. Step 1. Choose Wireless Settings  Basic to display the Basic Settings page. Figure 4-21 Step 2.
  • Page 63 User’s Manual of IAP-200x Series Figure 4-22 Step 4. Choose Wireless Settings > Security to display the Wireless Security Settings page. -62-...
  • Page 64: Station List

    User’s Manual of IAP-200x Series Figure 4-23 Step 5. In this page, set the security mode of IAP-2000 to accord with the peer router. 4.5.6. Station List The administrator can check the users connected to the IAP-2000 in this page. Figure 4-24 Click Refresh button to renew the list above immediately.
  • Page 65: Layer 2 Functions

    User’s Manual of IAP-200x Series 4.6. Layer 2 Functions Users can configure the port setting and VLAN in this page. The submenus of Layer 2 Functions is shown below: Figure 4-25 4.6.1. Port Status Users can check the information of the connection on each port in this page. Figure 4-26 Click Refresh button to renew the list above immediately.
  • Page 66: Port Setting

    User’s Manual of IAP-200x Series 4.6.2. Port Setting Users can enable or disable each port, and configure the related settings in this page. Figure 4-27 Fast Ethernet Port Configuration Object Description  Port This is the LAN port number for this row. ...
  • Page 67 User’s Manual of IAP-200x Series Figure 4-28 VLAN Mode Setting Mode: You can enable or disable the VLAN here.  Management VID VID: Set the management VLAN of the IAP-2000.  VLAN Member Configuration Object Description  VLAN Group: You can select enable or disable. ...
  • Page 68: Mac Address Table

    User’s Manual of IAP-200x Series 4.6.4. MAC Address Table It shows the MAC address for each port here. Figure 4-29 Click Refresh button to renew the list above immediately. 4.7. System Tools Users can configure the related settings of IAP-2000 system here. The submenus of System Tools option is shown below: Figure 4-30 -67-...
  • Page 69: Poe Configuration

    3~12 watts the installation time. IAP-2000PS is a PoE device of End-span PSE. In this page, you can monitor the power consumption of each device which is power supplied by IAP-2000PS and configure the related settings of PoE function. -68-...
  • Page 70 Object Description  Power Limit Mode: Allow to configure power limit mode for PoE PD devices connected with IAP-2000PS.  Port Priority: Deliver PoE power by port priority setting.  Total Limit: Set total limit value of all the POE ports to provide power for the PDs.
  • Page 71: Ipv6 Ping

    User’s Manual of IAP-200x Series maximum power that the PD will draw across all input voltages and operational modes. A PD shall return Class 0 to 3 in accordance with the maximum power draw.  Current [mA] It shows the current Amp of the PoE device. ...
  • Page 72: Upload Firmware

    User’s Manual of IAP-200x Series Object Description  IPv6 Address The destination of IPv6 Address.  Test Click the button to start transmitting PING packets.  Clear Message Clear the PING records below. 4.7.3. Upload Firmware In this page, you may upgrade the correct new version firmware to obtain new functionality. Figure 4-31 Update Firmware Location: Click Browse to select the firmware file, and click Apply to upgrade the firmware.
  • Page 73: Reboot

    User’s Manual of IAP-200x Series Figure 4-32 Export Settings Export Button: Click the Export to export the settings. Import Settings Settings file location: Click Browse to select the configuration file, and then click Import to upload the configuration file. Click Cancel to cancel the uploading operation. Load Factory Defaults Load Default Button: Click Load Default to make AP return to the default settings.
  • Page 74: Statistics

    User’s Manual of IAP-200x Series Figure 4-33 Click the “Reboot” button and the device will restart. 4.7.6. Statistics It displays the information about AP status, including system information, Internet configurations, and local network. Figure 4-34 -73-...
  • Page 75: System Log

    User’s Manual of IAP-200x Series 4.8. System Log The system log dialog allows you to view the system log and click the “Refresh” button to fresh the system event logs. You are allowed to view and disable / enable the system log in this page. Figure 4-35 Click Refresh to refresh the log.
  • Page 76: Chapter 5. Poe (Power Over Ethernet) Overview

    User’s Manual of IAP-200x Series Chapter 5. PoE (Power over Ethernet) Overview 5.1. What is PoE? Based on the global standard IEEE 802.3af, PoE is a technology for wired Ethernet, the most widely installed local area network technology adopted today. PoE allows the electrical power necessary for the operation of each end-device to be carried by data cables rather than by separate power cords.
  • Page 77 User’s Manual of IAP-200x Series Figure 5-2 Power Supplied over the Data Pins When to install PoE? Consider the following scenarios: • You're planning to install the latest VoIP Phone system to minimize cabling building costs when your company moves into new offices next month. •...
  • Page 78: Poe Provision Process

    User’s Manual of IAP-200x Series 5.2. PoE Provision Process While adding PoE support to networked devices is relatively painless, it should be realized that power cannot simply be transferred over existing CAT-5 cables. Without proper preparation, doing so may result in damage to devices that are not designed to support provision of power over their network interfaces.
  • Page 79 User’s Manual of IAP-200x Series 3. Start-up Once line detection and optional classification stages are completed, the PSE must switch from low voltage to its full voltage capacity (44-57 Volts) over a minimal amount of time (above 15 microseconds). A gradual startup is required, as a sudden rise in voltage (reaching high frequencies) would introduce noise on the data lines.
  • Page 80: Appendix A. Networking Connection

    User’s Manual of IAP-200x Series Appendix A. Networking Connection A.1. DATA OUT PoE Switch RJ-45 Port Pin Assignments (Port-1 to Port-4) PIN NO RJ-45 SIGNAL ASSIGNMENT  Output Transmit Data +  Power +  Output Transmit Data –  Power + ...
  • Page 81 User’s Manual of IAP-200x Series The standard cable, RJ-45 pin assignment Figure A-2 The standard RJ-45 receptacle/connector There are 8 wires on a standard UTP/STP cable and each wire is color-coded. The following shows the pin allocation and color of straight cable and crossover cable connection: Straight Cable SIDE 1 SIDE2...
  • Page 82 User’s Manual of IAP-200x Series EC Declaration of Conformity English Hereby, PLANET Technology Corporation, Lietuviškai Šiuo PLANET Technology Corporation,, skelbia, declares that this Industrial 802.11n Wireless AP is kad Industrial 802.11n Wireless AP tenkina visus in compliance with the essential requirements and svarbiausius 1999/5/EC direktyvos reikalavimus ir other relevant provisions of Directive 1999/5/EC.

This manual is also suitable for:

Iap-2000peIap-2001pe

Table of Contents