CALCIUM (BULK AND ABSORPTION 14.7 VOLTS, EQUALISATION AND
RECONDITION UP TO 16 VOLTS)
This charge mode is best suited for Calcium batteries that have been deeply discharged
and require an equalization charge to restore a full electrolyte reading. If the battery
requires a simple 'top-up', the WET charge mode can be used.
LOCKING THE BATTERY CHARGER SETTINGS
Locking the battery charger settings will disable the CHARGE RATE & MODE keys from
use. This function is ideal for hire vehicles etc as it prevents the chargers settings from
being altered if the keys are touched.
To lock; press and hold the 'CHARGE RATE' and 'MODE' keys for 3 seconds until all the
LEDs illuminate. This indicates the keys are now locked.
To unlock; press and hold and 'CHARGE RATE' and 'MODE' keys for 3 seconds until all
the LEDs illuminate. This indicates the keys are now unlocked.

FAULT CODES

There are three error codes that may be displayed. These will be displayed in the
following way:
Power
Charging
(Red LED)
(Blue LED)
___ ___ ___
(Slow Flash)
– – – – – – –
(Fast Flash)
___ ___ ___
(Slow Flash)
Full
(Green LED)
OFF
OFF
OFF
OFF
OFF
ON
Fault
Remedy
Short circuit
Check clips are not
or reverse
touching each other
connection
OR
of the clips
Check the clips are
correctly connected
to the battery
Bulk charging
Battery may
has timed out
be faulty
and stopped
after 22 hours
The charger
Battery may be
has entered
faulty and may
recondition mode
need replacing
3 times and has
OR
timed out
There is a load
on the battery
causing the battery
to fail Analysis