Hyundai GreenPower User Manual page 26

Portable inverter
Table of Contents

Advertisement

Available languages

Available languages

No DC output
Generator
Connected
outputs
device does
unstable
not operate
power
consistently
Device will not
start up
Engine idle
unusually high
or low
Generator
Operation is
overheats
normal when
generator
is cool,
overheating
occurs within
moments of
start up.
Engine idle
fluctuates
1. Disconnect battery, reset breaker and test the
battery for shorts.
2. Clean battery connector nodes.
Verify device start up requirements (Wattage
consumption). Do not exceed the generators
maximum peak output.
1. Remove all loads, reset breaker, and check
device for defects. Do not exceed generator
rating.
2. Ensure device's wattage consumption does
not exceed the generator's maximum peak
output.
Carburetor in need of tuning. For details on how to
adjust correctly please contact your local service
centre, or contact Midland Intl Inc. at 1-877-528-
3772.
1. Atmospheric temperature high (excess of
35°C).
2. Insufficient air circulation in vicinity of
generator.
3. Low oil viscosity, use 10W40 when
temperatures exceed 30°C, 10W30 for
temperatures between 0° ~ 30°C, and 5W40
for temperatures below 0°C.
4. Fouled spark plug, replace with equal or
greater quality plug.
1. Carburetor in need of tuning. For details on
how to adjust correctly please contact your
local service centre, or contact Midland Intl
Inc. at 1-877-528-3772. Missing ground
reference on return side of differential analog
output (external).
2. Air filter element obstructed by debris. Clean
according to user guide instructions on page
11.