Line Settings - JTECH TITAN User Manual

Telephone router
Hide thumbs Also See for TITAN:
Table of Contents

Advertisement

User Manual 
4.4
Line Settings 
To administer advanced phone line settings, click Input Lines ‐> Line Settings. 
 
Rx Gain – This field refers to the phone line sensitivity on the input side. Value range is from ‐16.5dB to 
+13.5dB. For example, if the Telephone Router is having trouble hearing DTMF key presses you could try 
typing a value of 3, 6, 9 or 12 dB here and check for improvements. 
 
Tx Gain – This field refers to the phone line sensitivity on the output side. Value range is from ‐16.5dB to 
+13.5dB. For example, if voice prompts are too quiet through the phone, you could try typing a value of 
3, 6, 9 or 12 dB here until the voice prompt is at the correct volume. 
 
Filter – The telephony lines support additional filter selections for the receive and transmit signals. This 
should normally be left at a value of 0. 
 
Hybrid 1‐8 – These fields are used to adjust the hybrid response to reduce near‐end echo in the eight‐tap 
filter. When these fields are set to all 0s, this filter stage does not have an effect on the hybrid response. 
 
Pulses Per Ring – This field adjusts how many pulses the Telephone Router will count as one ring. This 
should normally be left at a value of 20. 
© JTECH Communications, Inc. 
 
 
Telephone Router    
 
Page 33 

Advertisement

Table of Contents
loading

Related Products for JTECH TITAN

Table of Contents