7 7

Finishing

A. Facing Material
The fi replace structure can be covered with any non-
combustible material. Refer to Section 1.D.
It is possible for the face of the appliance above the ap-
pliance opening to show signs of soot. Clean that area as
frequently as necessary to eliminate a build up of soot or
permanent discoloration. A non-combustible ledge (shelf)
approximately 3 inches above the opening and a mini-
mum of 3 inches out from the face of the appliance incor-
porated into the facing material will help prevent the soot
from going up the wall.
WARNING! Risk of Fire! DO NOT apply combustible ma-
terials beyond the minimum clearances. Comply with all
minimum clearances to combustibles as specifi ed in this
manual. Overlapping materials could ignite.
Note: The control box lid can be painted as desired.
Use sandpaper or other abrasive material to scuff
the surface prior to painting.
Figure 7.1 Clearances to Mantels or other Combustibles above Appliance.
Outdoor Lifestyles by Hearth & Home Technologies Inc. • Carolina-B Installation Manual • 4066-500 Rev. B • 5/14
12 in. (305 mm)
max. combustible
mantel depth
B. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specifi ed. Framing or fi nishing
material closer than the minimums listed must be con-
structed entirely of noncombustible materials (i.e., steel
studs, concrete board, etc.).
Figure 7.1 shows the dimensions for mantels or other
combustible projections above the appliance opening.
Ceiling or
Overhang
25 in.
(635 mm)
minimum
21