Finishing; Mantel And Wall Projections; Facing Material - Outdoor Lifestyles Twilight-II-B Installation Manual

Installation and appliance setup
Hide thumbs Also See for Twilight-II-B:
Table of Contents

Advertisement

8 8

Finishing

A. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances as specifi ed. Framing closer than the minimums list-
ed must be constructed entirely of noncombustible materi-
als (i.e., steel studs, concrete board, etc.) Failure to comply
could cause fi re.
NON-COMBUSTIBLE BOARD
(SUPPLIED ON APPLIANCE)
INDOOR SIDE ONLY
Figure 8.1 Clearances to a Combustible and/or Non-combustible
Indoor Mantel
MEASURED
FROM CORNER
FIREPLACE
HOOD
Figure 8.2 Clearances to a Combustible and/or Non-combustible
Indoor Mantel or Mantel Leg
22
Outdoor Lifestyles by Hearth & Home Technologies • Twilight-II-B Installation Manual • 2108-970 Rev. H • 5/14
CEILING
12
11
10
35-3/4
9
8
7
13-5/8
12-5/8
6
11-5/8
10-5/8
9-5/8
8-5/8
7-5/8
HOOD
Note: Measurements are in inches.
TOP VIEW
1/2 IN.
B. Facing Material
Inside Facing Material
• May install combustible materials up to specified
clearances on top, front and sides of appliance.
• Seal joints between fi nished wall and appliance top and
sides with 300ºF (140º C) minimum sealant.
• Leave space so bottom grille can be lowered for trim
door removal.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specifi ed in
this manual. Overlapping materials could ignite and will
interfere with proper operation of doors and louvers.
NON-COMBUSTIBLE ZONE
41-7/8 in.
Figure 8.3 Non-combustible Zone (Interior)
Finishing Material Clearances
OVERHANG
FINISHING MATERIALS
A
SIDING
MINIMUM CLEARANCES
Vinyl
A
36 in.
B
64-5/16 in.
Figure 8.4 Exterior View - Finishing Material Clearances
2-3/4 in.
B
A
SIDING
A
SIDING
Non-vinyl
12 in.
35-5/16 in.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Twilightlp-ii-b

Table of Contents