Finishing; Mantel And Wall Projections; Facing Material - Outdoor Lifestyles TWILIGHT-II-MOD Owner's Manual

Gas fireplace
Hide thumbs Also See for TWILIGHT-II-MOD:
Table of Contents

Advertisement

10
10

Finishing

A. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances as specifi ed. Framing closer than the minimums list-
ed must be constructed entirely of noncombustible materi-
als (i.e., steel studs, concrete board, etc.) Failure to comply
could cause fi re.
NON-COMBUSTIBLE BOARD
(SUPPLIED ON APPLIANCE)
INDOOR SIDE ONLY
Figure 10.1 Clearances to a Combustible and/or Non-combustible
Indoor Mantel
MEASURED
FROM CORNER
FIREPLACE
HOOD
Figure 10.2 Clearances to a Combustible and/or Non-combustible
Indoor Mantel or Mantel Leg
Outdoor Lifestyles by Hearth & Home Technologies, Inc. • TWILIGHT-II-MOD • 2290-900 Rev. C • 7/12
CEILING
12
11
10
9
8
7
13-5/8
12-5/8
6
11-5/8
10-5/8
9-5/8
8-5/8
7-5/8
HOOD
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
Note: Measurements are in inches.
1/2 IN.
B. Facing Material
Inside Facing Material
• May install combustible materials up to specified
clearances on top, front and sides of appliance.
• Seal joints between fi nished wall and appliance top and
sides with 300ºF (140º C) minimum sealant.
• Leave space so bottom grille can be lowered for trim
door removal.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specifi ed in
this manual. Overlapping materials could ignite and will
35-3/4
interfere with proper operation of doors and louvers.
Figure 10.3 Non-combustible Zone (Interior)
SIDING
Figure 10.4 Exterior View - Finishing Material Clearances
NON-COMBUSTIBLE ZONE
41-7/8 in.
Finishing Material Clearances
OVERHANG
FINISHING MATERIALS
A
SIDING
MINIMUM CLEARANCES
Vinyl
A
36 in.
B
64-5/16 in.
2-3/4 in.
B
A
A
SIDING
Non-vinyl
12 in.
35-5/16 in.
29

Advertisement

Table of Contents
loading